I understand that themal cycle considerations are well documented and have good predictors of performance.  However, in harsh environments, drop shock and vibration are also failure mechanisms.  These have received relatively little performance prediction.  Seems to me, those factors are still in the "build some prototypes and try them out" stage.  

Any studies of equivalent BGA and LGA components in high stress or combined environments?   The LGAs will have very low solder joint height, but may perform better due to less component mass (weight of solder balls) in vibration and drop.  

Comments?

Denny Fritz










-----Original Message-----
From: Thayer, Wayne - IIW <[log in to unmask]>
To: [log in to unmask]
Sent: Thu, May 20, 2010 4:17 pm
Subject: [TN] Solder joint height


Should there be a spec for minimum solder joint height for leadless components?  
n old paper from Werner (mid 90's, I believe) popped up on the Internet when I 
ueried this, and Werner has a statement in it that joints less than about 50 
icrons thick are basically all intermetallics, but that is not necessarily a 
ad thing since the intermetallics are stronger than the solder (but more 
rittle).
I figured since we often try to get additional height for BGA joints to improve 
eliability, we should be concerned about QFNs and LCCs.
I grabbed a 1.5mil (37 micron) tungsten rod out of our cleanroom (used for 
learing clogged wirebond capillaries)and started seeing if I could get that 
nder my leadless components.  Couldn't get it under any of them, likewise with 
he QFNs.
Checked Technet archives and didn't see an obvious thread, but maybe I didn't 
ave the correct search parameters--if you just enter "height" you get a couple 
f thousand hits.
Wayne Thayer
This e-mail and any files transmitted with it may be proprietary and are 
ntended solely for the use of the individual or entity to whom they are 
ddressed. If you have received this e-mail in error please notify the sender.
lease note that any views or opinions presented in this e-mail are solely those 
f the author and do not necessarily represent those of ITT Corporation. The 
ecipient should check this e-mail and any attachments for the presence of 
iruses. ITT accepts no liability for any damage caused by any virus transmitted 
y this e-mail.
______________________________________________________________________
his email has been scanned by the MessageLabs Email Security System.
or more information please contact helpdesk at x2960 or [log in to unmask] 
_____________________________________________________________________
---------------------------------------------------
echnet Mail List provided as a service by IPC using LISTSERV 15.0
o unsubscribe, send a message to [log in to unmask] with following text in
he BODY (NOT the subject field): SIGNOFF Technet
o temporarily halt or (re-start) delivery of Technet send e-mail to 
[log in to unmask]: SET Technet NOMAIL or (MAIL)
o receive ONE mailing per day of all the posts: send e-mail to 
[log in to unmask]: SET Technet Digest
earch the archives of previous posts at: http://listserv.ipc.org/archives
lease visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for 
dditional information, or contact Keach Sasamori at [log in to unmask] or 
47-615-7100 ext.2815
----------------------------------------------------


______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2