You speak about so and so percentage of voíds in the SJs. Bart Vandevelde 
presented,  a number of years ago, results from evaluation of solder joint 
void in CSP. FC, BGA and the void size vs. strain during temp cycling. 
Voids as big as 75 % did not cause significant stress, while a number of 
very small voids caused noticable stress, namely, because they were adjacent 
to each other,  in a row, so as to say.  So maybe one stops packages with a 
large void and lets go a package with a number of small voids.

Inge

--------------------------------------------------
From: "Bev Christian" <[log in to unmask]>
Sent: den 4 May 2010 14:22
To: <[log in to unmask]>
Subject: Re: [TN] Question about Voids in Solder Joints

> Underway.  THAT I will not be able to share.
> Bev
> RIM
>
> -----Original Message-----
> From: TechNet [mailto:[log in to unmask]] On Behalf Of Victor Hernandez
> Sent: Tuesday, May 04, 2010 8:01 AM
> To: [log in to unmask]
> Subject: Re: [TN] Question about Voids in Solder Joints
>
> Was a deep dive conducted on field return fsilure to attribute the
> failure to leaded component voiding?
>
> Victor,
>
> -----Original Message-----
> From: TechNet [mailto:[log in to unmask]] On Behalf Of Bev Christian
> Sent: Monday, May 03, 2010 7:24 PM
> To: [log in to unmask]
> Subject: Re: [TN] Question about Voids in Solder Joints
>
> Thanks, George. Most detailed answer yet.
>
> At Nortel we never had a void spec for leaded components either. And, as
> I
> think I have said on TechNet before, we would find many joints after
> pull
> testing or cross-sectioning that looked like Swiss cheese, but we never
> had
> field failures as a result.  BUT we were manly concerned about the
> possibility of failures due to thermal cycling.
>
> Now I worked for a company where the main concern is customers dropping
> their product onto hard edges.  We do a lot of work to try and design
> and
> build products to survive multiple drops in different orientations, but
> occasionally a switch is going to come down on a pointed rock or a
> customer
> is going to rip a charging cable out of a connector at a 45 degree angle
> (yikes).  These are the things I am talking about.  I was leaning
> towards
> 25% for leaded components, so you and I are in the same ball park,
> George.
> Others have suggested a higher number, but without some encouraging
> words in
> that direction from fellow TechNetters, I ain't goin' there.
> Bev
> RIM
>
> -----Original Message-----
> From: TechNet [mailto:[log in to unmask]] On Behalf Of Wenger, George M.
> Sent: Monday, May 03, 2010 5:57 PM
> To: [log in to unmask]
> Subject: Re: [TN] Question about Voids in Solder Joints
>
> Bev,
>
> We're in a similar position to Dave Hillman.  We basically follow IPC
> standards (where there are standards).  We do not have a company
> standard
> for leaded components.  A couple of small voids is okay, more or large
> voids
> are not.  Having said that you'll probably ask how many is a couple and
> what
> is small and what is large.  We don't have a really good answer.  Since
> we
> do a lot of RF power component work we've adopted a voiding
> specification
> that has worked well for IC packages.  They typically use a criteria of
> total die attach voids <20% with no single void >5% is okay. We don't
> actually measure voids in leaded devices but if we were to see 20%
> voiding
> in a leaded component solder joint we'd be concerned.
>
> Regards,
> George
> George M. Wenger
> Senior Principal FMA  / Reliability Engineer
> Andrew Corporation - Wireless Network Solutions
> 40 Technology Drive, Warren, NJ 07059
> (908) 546-4531 Office (732) 309-8964 Mobile
> E-mail: [log in to unmask]
> -----Original Message-----
> From: TechNet [mailto:[log in to unmask]] On Behalf Of Bev Christian
> Sent: Monday, May 03, 2010 3:48 PM
> To: [log in to unmask]
> Subject: [TN] Question about Voids in Solder Joints
>
> TechNetters,
> I was thinking about just putting "Voiding" as the e-mail title, but I
> contemplated what I might get in responses and amended my title
> accordingly.
>
> My question is the following: do any of your companies have upper limits
> on the amount of voiding in SMT solder joints of components that
> customers have access to - like connectors and switches?  These of
> course are leaded components.  I am not talking about Pb, but the form
> of the interconnect between the component body and the board.
>
> If so, are you willing and can you share?
>
> Bev
> RIM
>
> ---------------------------------------------------------------------
> This transmission (including any attachments) may contain confidential
> information, privileged material (including material protected by the
> solicitor-client or other applicable privileges), or constitute
> non-public
> information. Any use of this information by anyone other than the
> intended
> recipient is prohibited. If you have received this transmission in
> error,
> please immediately reply to the sender and delete this information from
> your
> system. Use, dissemination, distribution, or reproduction of this
> transmission by unintended recipients is not authorized and may be
> unlawful.
>
> ______________________________________________________________________
> This email has been scanned by the MessageLabs Email Security System.
> For more information please contact helpdesk at x2960 or
> [log in to unmask]
> ______________________________________________________________________
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 15.0
> To unsubscribe, send a message to [log in to unmask] with following text
> in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to
> [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at:
> http://listserv.ipc.org/archives
> Please visit IPC web site
> http://www.ipc.org/contentpage.asp?Pageid=4.3.16
> for additional information, or contact Keach Sasamori at [log in to unmask]
> or
> 847-615-7100 ext.2815
> -----------------------------------------------------
>
> ______________________________________________________________________
> This email has been scanned by the MessageLabs Email Security System.
> For more information please contact helpdesk at x2960 or
> [log in to unmask]
> ______________________________________________________________________
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 15.0
> To unsubscribe, send a message to [log in to unmask] with following text
> in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to
> [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at:
> http://listserv.ipc.org/archives
> Please visit IPC web site
> http://www.ipc.org/contentpage.asp?Pageid=4.3.16
> for additional information, or contact Keach Sasamori at [log in to unmask]
> or
> 847-615-7100 ext.2815
> -----------------------------------------------------
>
>
> ______________________________________________________________________
> This email has been scanned by the MessageLabs Email Security System.
> For more information please contact helpdesk at x2960 or
> [log in to unmask]
> ______________________________________________________________________
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 15.0
> To unsubscribe, send a message to [log in to unmask] with following text
> in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to
> [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at:
> http://listserv.ipc.org/archives
> Please visit IPC web site
> http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
> information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
> ext.2815
> -----------------------------------------------------
>
> ______________________________________________________________________
> This email has been scanned by the MessageLabs Email Security System.
> For more information please contact helpdesk at x2960 or
> [log in to unmask]
> ______________________________________________________________________
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 15.0
> To unsubscribe, send a message to [log in to unmask] with following text
> in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to
> [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at:
> http://listserv.ipc.org/archives
> Please visit IPC web site
> http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
> information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
> ext.2815
> -----------------------------------------------------
>
> ---------------------------------------------------------------------
> This transmission (including any attachments) may contain confidential 
> information, privileged material (including material protected by the 
> solicitor-client or other applicable privileges), or constitute non-public 
> information. Any use of this information by anyone other than the intended 
> recipient is prohibited. If you have received this transmission in error, 
> please immediately reply to the sender and delete this information from 
> your system. Use, dissemination, distribution, or reproduction of this 
> transmission by unintended recipients is not authorized and may be 
> unlawful.
>
> ______________________________________________________________________
> This email has been scanned by the MessageLabs Email Security System.
> For more information please contact helpdesk at x2960 or [log in to unmask]
> ______________________________________________________________________
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 15.0
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to 
> [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to 
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/archives
> Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 
> for additional information, or contact Keach Sasamori at [log in to unmask] or 
> 847-615-7100 ext.2815
> -----------------------------------------------------  


______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2