Hi Bev - my personal opinion is that a void neither enhances (i.e. acts as 
a crack stopper) nor degrades solder joint reliability unless you reach a 
threshold where the void has physically reduced the overall solder joint 
area thus making the distance a crack has to progress to fail a solder 
joint critically short. There are a number of published industry reports 
that would support that hypothesis. I would follow the logic path that 
George does for his RF applications - what size or total amount of voiding 
impacts the functionality of the product application. In your case, you 
are looking for a solder joint area for a variety of component styles that 
can withstand the rigors of dropping a hand held device. The drop test 
idea that Ioan proposed could be a way to derive a data set. And you avoid 
(yes, that was an intentional pun) having to make voids by creating solder 
joints of different areas for testing. And it would be a really good co-op 
project! Good Luck.

Dave



Bev Christian <[log in to unmask]> 
Sent by: TechNet <[log in to unmask]>
05/03/2010 07:24 PM
Please respond to
TechNet E-Mail Forum <[log in to unmask]>; Please respond to
Bev Christian <[log in to unmask]>


To
[log in to unmask]
cc

Subject
Re: [TN] Question about Voids in Solder Joints






Thanks, George. Most detailed answer yet.

At Nortel we never had a void spec for leaded components either. And, as I
think I have said on TechNet before, we would find many joints after pull
testing or cross-sectioning that looked like Swiss cheese, but we never 
had
field failures as a result.  BUT we were manly concerned about the
possibility of failures due to thermal cycling.

Now I worked for a company where the main concern is customers dropping
their product onto hard edges.  We do a lot of work to try and design and
build products to survive multiple drops in different orientations, but
occasionally a switch is going to come down on a pointed rock or a 
customer
is going to rip a charging cable out of a connector at a 45 degree angle
(yikes).  These are the things I am talking about.  I was leaning towards
25% for leaded components, so you and I are in the same ball park, George.
Others have suggested a higher number, but without some encouraging words 
in
that direction from fellow TechNetters, I ain't goin' there.
Bev
RIM 

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Wenger, George M.
Sent: Monday, May 03, 2010 5:57 PM
To: [log in to unmask]
Subject: Re: [TN] Question about Voids in Solder Joints

Bev,

We're in a similar position to Dave Hillman.  We basically follow IPC
standards (where there are standards).  We do not have a company standard
for leaded components.  A couple of small voids is okay, more or large 
voids
are not.  Having said that you'll probably ask how many is a couple and 
what
is small and what is large.  We don't have a really good answer.  Since we
do a lot of RF power component work we've adopted a voiding specification
that has worked well for IC packages.  They typically use a criteria of
total die attach voids <20% with no single void >5% is okay. We don't
actually measure voids in leaded devices but if we were to see 20% voiding
in a leaded component solder joint we'd be concerned. 

Regards,
George
George M. Wenger
Senior Principal FMA  / Reliability Engineer
Andrew Corporation - Wireless Network Solutions
40 Technology Drive, Warren, NJ 07059
(908) 546-4531 Office (732) 309-8964 Mobile
E-mail: [log in to unmask]
-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Bev Christian
Sent: Monday, May 03, 2010 3:48 PM
To: [log in to unmask]
Subject: [TN] Question about Voids in Solder Joints

TechNetters,
I was thinking about just putting "Voiding" as the e-mail title, but I
contemplated what I might get in responses and amended my title
accordingly.

My question is the following: do any of your companies have upper limits
on the amount of voiding in SMT solder joints of components that
customers have access to - like connectors and switches?  These of
course are leaded components.  I am not talking about Pb, but the form
of the interconnect between the component body and the board.

If so, are you willing and can you share?

Bev
RIM

---------------------------------------------------------------------
This transmission (including any attachments) may contain confidential
information, privileged material (including material protected by the
solicitor-client or other applicable privileges), or constitute non-public
information. Any use of this information by anyone other than the intended
recipient is prohibited. If you have received this transmission in error,
please immediately reply to the sender and delete this information from 
your
system. Use, dissemination, distribution, or reproduction of this
transmission by unintended recipients is not authorized and may be 
unlawful.

______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------


______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to 
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to 
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 
for additional information, or contact Keach Sasamori at [log in to unmask] or 
847-615-7100 ext.2815
-----------------------------------------------------



______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2