As I've been involved in many q about leakage (we've designed several PWBs 
with many kV WV) I wonder if not there is a close relation between CAF and 
leakage current?
E.g. NPL MATC(A)155 which reports CAF as and effect of:

- via-to-via gap
- layout
- via alignment to glass weave
- inner layer pads and polarity
- board surface finish
-drill feed speed
- reflow conditions
- board manufacturing location
- glass transition temp
- glass reinforcement
- laminate chemistry

As I can see it,  leakage current  is not isolated from CAF.

just a thought

Inge








--------------------------------------------------
From: "Inge" <[log in to unmask]>
Sent: den 4 May 2010 00:13
To: "Inge" <[log in to unmask]>; <[log in to unmask]>
Subject: Re: [TN] Question for High Voltage guru's

>
> Some guys have contacted me offline to get more about the statement below.
> It's a factor following Arrhenius's law.  I could not promptly find  a 
> reference specifically for leakage,
> but the pasted lines that follow are in principal same for leakage current 
> (and some more ).  Agree, very little is written
> about this in our PWB correspondence, but I'm sure one can find it 
> somewhere in TN's archive.
> Also, it may also  be in Earl Moon's POD Handbook: 
> http://www.dynamixtechnology.com/publications.htm.  I got a copy directly 
> from Earl, but I cannot find it for the moment . His handbook is something 
> all should have working with electronics.
>
> Inge
>
> One cause of temperature related failures of boards or components relates 
> to change or degradation at the molecular level. This type of failure is 
> best modeled as a first order kinetic reaction, typically described as an 
> Arrhenius Equation, which is proportional to the inverse log of the 
> temperature. A simplified Arrhenius equation and a resulting reliability 
> plot against operating temperature are displayed in FIGURE 2. Since 
> failure rates, often described as a mean-time-to-failure (MTTF), increase 
> exponentially with temperature, a 10° C-increase in temperature can double 
> the failure rate. In an operating device where reliability is critical to 
> success, even 1° C can matter. The key to improving reliability is to 
> reduce device temperature by increasing the rate at which heat is removed 
> from the device and from the working area of the PCB immediately adjacent 
> to the device. Understanding heat transfer then becomes the next step.
>
>
> --------------------------------------------------
> From: "Inge" <[log in to unmask]>
> Sent: den 3 May 2010 20:34
> To: <[log in to unmask]>
> Subject: Re: [TN] Question for High Voltage guru's
>
>> Add this :  leakage currents double for each 10 Centigrades  of operating 
>> temperature
>>
>> Inge
>>
>> --------------------------------------------------
>> From: "Paul Edwards" <[log in to unmask]>
>> Sent: den 3 May 2010 20:01
>> To: <[log in to unmask]>
>> Subject: Re: [TN] Question for High Voltage guru's
>>
>>> Colin,
>>>
>>> How close is the nearest ground in your PCB?
>>>
>>> How is the HV routed to the exposed metal pad that I assume is 
>>> Au-plated?
>>>
>>> Have built RoHS PCAs with FR-4 type PCB material at +3kv operating and 
>>> found that the leakage path between the HV via and the GND run along the 
>>> glass reinforcing bundles until they plate a circuit and short out the 
>>> HV supply, unless the open air load is a lower resistance path...
>>>
>>> Rotate the weave, offset the via grids, bake the laminates and seal the 
>>> PCB...
>>>
>>> Paul
>>>
>>> Paul Edwards
>>> Surface Art Engineering
>>>
>>> -----Original Message-----
>>> From: TechNet [mailto:[log in to unmask]] On Behalf Of colin mcvean
>>> Sent: Monday, May 03, 2010 12:00 AM
>>> To: [log in to unmask]
>>> Subject: [TN] Question for High Voltage guru's
>>>
>>> Ladies and Gentlemen of Technet-land,
>>>
>>> Let's consider an application based on FR4, originally manufactured on 
>>> ceramic base materials:
>>>
>>> It generates a plasma field from the surrounding air, neutralizing any 
>>> airborne particals and nasties!
>>>
>>> It operates at around 3KV, for a period of time then resets.
>>>
>>> Given passivation layers of FR4 are varied dependant on laminate 
>>> suppliers supply-chain at the time of lamination, then what influence 
>>> will this change have? i.e. Would I expect to see any issues with 
>>> different copper suppliers and passivation types?
>>>
>>> note: Qualification testing is under load 20% of the time at 3KV under 
>>> 85/85 damp heat conditions for 1000 hours. It has been qualified on 
>>> original FR-4 samples, but now I'm worried about this potential change 
>>> from my laminate supplier.
>>>
>>> looking forward as usual to comments and advice
>>>
>>> Colin
>>>
>>>
>>>
>>>
>>> ______________________________________________________________________
>>> This email has been scanned by the MessageLabs Email Security System.
>>> For more information please contact helpdesk at x2960 or 
>>> [log in to unmask]
>>> ______________________________________________________________________
>>>
>>> ---------------------------------------------------
>>> Technet Mail List provided as a service by IPC using LISTSERV 15.0
>>> To unsubscribe, send a message to [log in to unmask] with following text 
>>> in
>>> the BODY (NOT the subject field): SIGNOFF Technet
>>> To temporarily halt or (re-start) delivery of Technet send e-mail to 
>>> [log in to unmask]: SET Technet NOMAIL or (MAIL)
>>> To receive ONE mailing per day of all the posts: send e-mail to 
>>> [log in to unmask]: SET Technet Digest
>>> Search the archives of previous posts at: 
>>> http://listserv.ipc.org/archives
>>> Please visit IPC web site 
>>> http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional 
>>> information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 
>>> ext.2815
>>> -----------------------------------------------------
>>>
>>>
>>> ==============================================================================
>>>
>>> This email and any attachments thereto may contain private, 
>>> confidential, and
>>> privileged material for the sole use of the intended recipient. Any 
>>> review, copying,
>>> or distribution of this email (or any attachments thereto) by others is 
>>> strictly prohibited.
>>> If you are not the intended recipient, please contact 
>>> [log in to unmask]
>>> immediately and permanently delete the original and any copies of this 
>>> email and
>>> any attachments thereto.
>>>
>>> ==============================================================================
>>>
>>>
>>> ______________________________________________________________________
>>> This email has been scanned by the MessageLabs Email Security System.
>>> For more information please contact helpdesk at x2960 or 
>>> [log in to unmask]
>>> ______________________________________________________________________
>>>
>>> ---------------------------------------------------
>>> Technet Mail List provided as a service by IPC using LISTSERV 15.0
>>> To unsubscribe, send a message to [log in to unmask] with following text 
>>> in
>>> the BODY (NOT the subject field): SIGNOFF Technet
>>> To temporarily halt or (re-start) delivery of Technet send e-mail to 
>>> [log in to unmask]: SET Technet NOMAIL or (MAIL)
>>> To receive ONE mailing per day of all the posts: send e-mail to 
>>> [log in to unmask]: SET Technet Digest
>>> Search the archives of previous posts at: 
>>> http://listserv.ipc.org/archives
>>> Please visit IPC web site 
>>> http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional 
>>> information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 
>>> ext.2815
>>> ----------------------------------------------------- 
>>
>>
>> ______________________________________________________________________
>> This email has been scanned by the MessageLabs Email Security System.
>> For more information please contact helpdesk at x2960 or [log in to unmask] 
>> ______________________________________________________________________
>>
>> ---------------------------------------------------
>> Technet Mail List provided as a service by IPC using LISTSERV 15.0
>> To unsubscribe, send a message to [log in to unmask] with following text in
>> the BODY (NOT the subject field): SIGNOFF Technet
>> To temporarily halt or (re-start) delivery of Technet send e-mail to 
>> [log in to unmask]: SET Technet NOMAIL or (MAIL)
>> To receive ONE mailing per day of all the posts: send e-mail to 
>> [log in to unmask]: SET Technet Digest
>> Search the archives of previous posts at: 
>> http://listserv.ipc.org/archives
>> Please visit IPC web site 
>> http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional 
>> information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 
>> ext.2815
>> ----------------------------------------------------- 
> 

______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2