Hi Genny - yes, these structures have been reported in the industry before
so you are in luck. If these were tin/lead solderballs, you most likely
are looking at copper/tin intermetallic needles structures and if these
are SAC305 solderballs, you are most likely looking at silver/nickel
intermetallic needles. These structures are an indication that the
original reflow solder profile or the rework profile was temperature/time
excessive. Once the intermetallic phases form, they have melting points
much higher than the surrounding solder so when you removed the BGA
component, they become more visible as the solder joint volume is removed.
A second root cause would be incorrect metallurgical composition issues.
Nice photo - the first one is going into my photo gallery. Do you have any
higher magnification shots?
Dave Hillman
Rockwell Collins
[log in to unmask]
Genny Gibbard <[log in to unmask]>
Sent by: TechNet <[log in to unmask]>
05/28/2010 12:52 PM
Please respond to
TechNet E-Mail Forum <[log in to unmask]>; Please respond to
Genny Gibbard <[log in to unmask]>
To
[log in to unmask]
cc
Subject
[TN] Crystalline solder balls
http://ipc-technet.groupsite.com/gallery/13595
May not get many responses on a Friday before a long weekend, but your
ideas on what I am seeing is appreciated.
Sorry the camera on our microscope is not great.
This is some of what remains on a board after a BGA is removed with a
Summit hot air rework station.
> Genny
______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------
______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|