Hi all,

I'm hoping that this may find someone in our group that might have a suggestion.

We manufacture an X-ray source that we have traditionally used Polaroid 4x5 single sheet film and a lead aperture to determine if our system is in alignment.  Polaroid film is no longer available so we need a viable replacement.  Intraoral (bite wing) dental sensors work great but are too small in sensing area.  We need something that is approximately 2" x 3" and ideally would connect via USB.  Our energy can be adjusted easily from 40keV to 160keV and the exposure time can be adjusted to fit within the requirements of the sensor.  We need a single sensor for this routine test application that is reasonable priced.

Sales answers can be provided offline.

Thanks in advance,

Phil Nutting
Design for Manufacturing Engineer
Kaiser Systems, Inc.
126 Sohier Road
Beverly, MA 01915
voice: 978-922-9300 x1310
fax: 978-922-8374
e-mail: [log in to unmask]
www.kaisersystems.com
http://www.linkedin.com/in/philnutting

Note: All the information contained in this e-mail and its attachments is proprietary to Kaiser Systems, Inc. and it may not be reproduced without the prior written permission of sender.  If you have received this email in error, please immediately return it to sender and delete the copy you received.



______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2