Hi Bev,

Don't leave us hanging, what components are you seeing that with? I'd like 
to have a "heads-up".

This begs the question, why do you think they are doing that? Are things 
getting so tight that they're trying to pinch a penny by reducing plating 
coverage? Hmmmm...

Steve

----- Original Message ----- 
From: "Bev Christian" <[log in to unmask]>
To: <[log in to unmask]>
Sent: Thursday, March 25, 2010 9:08 PM
Subject: [TN] Need some opinions


> Technetters,
> It seems that more and more component suppliers are not plating their 
> leads
> all the way up to the component body. In fact some are getting downright
> skimpy and only plating to the bottom bend, never mind the upper one. If 
> you
> put down a lot of solder paste you end up with a bulbous joint, a negative
> wetting angle and a stress concentration point. If you put down less paste
> and have a co-planarity issue, then you have the potential for opens.  The
> other option of course is getting the supplier to plate higher up the 
> leads.
>
> Question: would you consider the condition of the formation of the 
> negative
> wetting angles a failure during process qualification?
>
> Bev
> RIM
>
>
> ______________________________________________________________________
> This email has been scanned by the MessageLabs Email Security System.
> For more information please contact helpdesk at x2960 or [log in to unmask]
> ______________________________________________________________________
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 15.0
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to 
> [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to 
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/archives
> Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 
> for additional information, or contact Keach Sasamori at [log in to unmask] or 
> 847-615-7100 ext.2815
> ----------------------------------------------------- 


______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2