Googled the following:

ElectroStatic Discharge : PRACTICAL ANALOG SEMICONDUCTOR CIRCUITS
Moving air can also generate substantial staticcharges. When you blow  
dust off your electronics their will be static generated. …
www.allaboutcircuits.com/../1.html - Options


Moving air can also generate substantial static charges. When you blow  
dust off your electronics their will be static generated. An  
industrial solution to the problem to this issue is two fold: Firstly,  
air guns have a small, well shielded radioactive material implanted  
within the airgun to ionize the air. Ionized air is a conductor, and  
will bleed off static charges quite well. Secondly, use high voltage  
electricity to ionize the air coming out of a fan, which has the same  
effect as the air gun. This will effectively help a workstation reduce  
the potential for ESD generation by a large amount.

-Bob Landman

Sent from my iPhone

On Mar 24, 2010, at 5:14 AM, Mike Fenner <[log in to unmask]> wrote:

> I'm not an ESD expert... so treat the following with caution, as it  
> may not
> be the same situation.
>
> A similar concern was raised by a customer after I recommended  
> forced air
> cooling after reflow. "Floating body charging" or similar words.
> Not being an expert and thinking this could be of more general  
> concern, I
> got a static expert and his gear and we spent an interesting few  
> hours with
> meters, ionizers, blowers, factory airlines and so on and found .....
> nothing.
> We rationalised that the stream carrying charges to the work, would
> similarly allow a path from the work. That accidental gas ionizing  
> was no
> different (apart from the cash) to deliberate ionising.
>
> Does this make sense?
>
>
>
> Regards
>
> Mike
>
> -----Original Message-----
> From: TechNet [mailto:[log in to unmask]] On Behalf Of Thayer, Wayne -  
> IIW
> Sent: Tuesday, March 23, 2010 9:51 PM
> To: [log in to unmask]
> Subject: [TN] air or nitrogen for drying
>
> We have a number of "airbrush" low pressure nozzles around here for  
> spraying
> solvents on reworked boards and for drying them off.  I know that  
> nozzles
> can create static, but I have had no problems to date and have had no
> problem with dust sticking to the boards when I dry them off this way.
>
> I haven't been able to find anything on trying to quantify static from
> nozzles used in this way.  Does anyone have data?  Moving to ionized
> blow-off for drying the boards would be painful, as that means yet  
> more
> equipment in our small cleaning stations.
>
> Wayne Thayer
>
> ________________________________
> This e-mail and any files transmitted with it may be proprietary and  
> are
> intended solely for the use of the individual or entity to whom they  
> are
> addressed. If you have received this e-mail in error please notify the
> sender.
> Please note that any views or opinions presented in this e-mail are  
> solely
> those of the author and do not necessarily represent those of ITT
> Corporation. The recipient should check this e-mail and any  
> attachments for
> the presence of viruses. ITT accepts no liability for any damage  
> caused by
> any virus transmitted by this e-mail.
>
> ______________________________________________________________________
> This email has been scanned by the MessageLabs Email Security System.
> For more information please contact helpdesk at x2960 or [log in to unmask]
> ______________________________________________________________________
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 15.0
> To unsubscribe, send a message to [log in to unmask] with following  
> text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to
> [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/archives
> Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
> for additional information, or contact Keach Sasamori at [log in to unmask] 
>  or
> 847-615-7100 ext.2815
> -----------------------------------------------------
>
>
> ***This email, its content, and any files transmitted with it, are  
> intended solely for the addressee(s) and may be legally privileged  
> and/or confidential. If you are not the intended recipient, please  
> contact the sender by return and delete the material from any  
> computer. Any review, retransmission, dissemination, or other use  
> of, or taking of any action in reliance upon this information by  
> persons or entities other than the intended recipient is prohibited.
>
>
> ______________________________________________________________________
> This email has been scanned by the MessageLabs Email Security System.
> For more information please contact helpdesk at x2960 or [log in to unmask]
> ______________________________________________________________________
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 15.0
> To unsubscribe, send a message to [log in to unmask] with following  
> text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask] 
> : SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask] 
> : SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/archives
> Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 
>  for additional information, or contact Keach Sasamori at [log in to unmask] 
>  or 847-615-7100 ext.2815
> -----------------------------------------------------
>

______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2