Contact Trek Inc in upstate NY as they make a variety of static  
voltmeters (3M and others rebrand their products).  Perhaps they will  
have advice for you on what can be done.

One suggestion, as I had the opposite problem years ago, doing  
consulting on a manufacturing line using Binks sprayers to spray  
adhesive on lids for 55 gal food barrels.  Automation then placed o- 
rings into the adhesive.

No adhesive then the next step placed the lids on the barrels and the  
o-rings would fall into the food.  Oops!

Problem was the sprayers clogged periodically.  So the company had a  
person watching the sprayers....

My solution was to charge the sprayer tips with 10v then use a Trek  
electrostatic voltmeter to measure the charge deposited on the lids.   
No charge, stop the line and clean the spray tips.

Watching job eliminated.

You have the reverse problem so I would suggest grounding the air jet  
tips  then measure with the Trek voltmeter.

Bob Landman

Sent from my iPhone

On Mar 23, 2010, at 5:50 PM, "Thayer, Wayne - IIW"  
<[log in to unmask]> wrote:

> We have a number of "airbrush" low pressure nozzles around here for  
> spraying solvents on reworked boards and for drying them off.  I  
> know that nozzles can create static, but I have had no problems to  
> date and have had no problem with dust sticking to the boards when I  
> dry them off this way.
>
> I haven't been able to find anything on trying to quantify static  
> from nozzles used in this way.  Does anyone have data?  Moving to  
> ionized blow-off for drying the boards would be painful, as that  
> means yet more equipment in our small cleaning stations.
>
> Wayne Thayer
>
> ________________________________
> This e-mail and any files transmitted with it may be proprietary and  
> are intended solely for the use of the individual or entity to whom  
> they are addressed. If you have received this e-mail in error please  
> notify the sender.
> Please note that any views or opinions presented in this e-mail are  
> solely those of the author and do not necessarily represent those of  
> ITT Corporation. The recipient should check this e-mail and any  
> attachments for the presence of viruses. ITT accepts no liability  
> for any damage caused by any virus transmitted by this e-mail.
>
> ______________________________________________________________________
> This email has been scanned by the MessageLabs Email Security System.
> For more information please contact helpdesk at x2960 or [log in to unmask]
> ______________________________________________________________________
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 15.0
> To unsubscribe, send a message to [log in to unmask] with following  
> text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask] 
> : SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask] 
> : SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/archives
> Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 
>  for additional information, or contact Keach Sasamori at [log in to unmask] 
>  or 847-615-7100 ext.2815
> -----------------------------------------------------
>

______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2