Wayne,

We use Nitrogen through an ionizing controller called a Pulseflow 
Controller. 
To check it I have a static meter, intentionally charge a surface, usually 
a piece of Mylar or Kapton, and use the ionized nitrogen gun for a few 
seconds.  I read the charge before and after.


Chuck Brummer
3M Manufacturing Engineer
8357 Canoga Ave.
Canoga Park, CA 91304-2605
(818) 734-4930




From:
"Thayer, Wayne - IIW" <[log in to unmask]>
To:
[log in to unmask]
Date:
03/23/2010 02:57 PM
Subject:
[TN] air or nitrogen for drying
Sent by:
TechNet <[log in to unmask]>



We have a number of "airbrush" low pressure nozzles around here for 
spraying solvents on reworked boards and for drying them off.  I know that 
nozzles can create static, but I have had no problems to date and have had 
no problem with dust sticking to the boards when I dry them off this way.

I haven't been able to find anything on trying to quantify static from 
nozzles used in this way.  Does anyone have data?  Moving to ionized 
blow-off for drying the boards would be painful, as that means yet more 
equipment in our small cleaning stations.

Wayne Thayer

________________________________
This e-mail and any files transmitted with it may be proprietary and are 
intended solely for the use of the individual or entity to whom they are 
addressed. If you have received this e-mail in error please notify the 
sender.
Please note that any views or opinions presented in this e-mail are solely 
those of the author and do not necessarily represent those of ITT 
Corporation. The recipient should check this e-mail and any attachments 
for the presence of viruses. ITT accepts no liability for any damage 
caused by any virus transmitted by this e-mail.

______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to 
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to 
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 
for additional information, or contact Keach Sasamori at [log in to unmask] or 
847-615-7100 ext.2815
-----------------------------------------------------





______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2