Can you tell me what type of coating this is (generic terms OK) and how
thick you suspect it is on the assembly?

Also do you see the same type of effect on the other side of the
assembly? 

Rich Kraszewski
(920)969-6075
-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Rob Strecker
Sent: Monday, March 22, 2010 2:46 PM
To: [log in to unmask]
Subject: [TN] Conformal Coating Issue?

Hi all,
We have an issues with one of our customers that we build PCA's for.
After we complete the build the customer sends it out for conformal
coating.  It appears the coating or florecent does not like via holes.
I believe they are still getting good coverage and I don't think this is
a dewetting problem as there is still coating present in the darker
locations.  I don't see these boards after they get coating but that's
what I am tolled.

These boards are double sided, lead free using water soluble paste/flux
washed in a batch cleaner with a 6% chemical concentration.  We go
through many rinse cycles and clean to 1.4Meg (resistivity monitoring of
the rinse water, for what it's worth).

What might the casue of this be?... wash solution in the vias??  Below
is a link to the picture.

http://ipc-technet.groupsite.com/galleries/photo/117131


Rob

______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or
[log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------

______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2