On an .062" or greater you can repair a press fit connector twice. 

Before scraping a board you could always solder the leads to assure good reliability since after this point you have nothing to loose.  

The reliability information for a specific press pin design is reported in the documentation of the manufacturer. 

I've attached one such document.IPC-A-610 only covers insertion angle, spacing to board and damage to pin or housing. 

http://www.btipnow.com/library/white_papers/Reliability%20of%20PressFIT%20Connections.pdf 

Under reliability 2 more insertions are allowed. 

I hope this is helpful. 

 John Goulet 

process Engineer 


----- Original Message ----- 
From: "Linda Langley" <[log in to unmask]> 
To: [log in to unmask] 
Sent: Monday, March 1, 2010 6:07:06 AM GMT -05:00 US/Canada Eastern 
Subject: [TN] Press fit connectors 

Does IPC rework standards have anything regarding EPT press fit 
connectors? 

  

We have expressed our concerns (multiple times) with reworking any type 
of press fit connectors to the customer and they are still pushing BU to 
agree to the rework, they don't want to scrap $$$ a bunch of product. 

  

Hopefully we can direct the customer to a IPC standard or white 
paper/study 

  

  

Linda Langley CIT 

Training Specialist 

Jabil Circuit 

248-292-6176 


The information in this email is confidential and may be legally privileged. It is intended solely for the addressee. Access to this email by anyone else is unauthorized. If you are not the intended recipient, any review, disclosure, copying, distribution or any action taken or omitted to be taken in reliance on it, is prohibited and may be unlawful. If you have received this in error, please inform the sender and /or addressee immediately and delete the material. Thank you. 


______________________________________________________________________ 
This email has been scanned by the MessageLabs Email Security System. 
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________ 

--------------------------------------------------- 
Technet Mail List provided as a service by IPC using LISTSERV 15.0 
To unsubscribe, send a message to [log in to unmask] with following text in 
the BODY (NOT the subject field): SIGNOFF Technet 
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL) 
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest 
Search the archives of previous posts at: http://listserv.ipc.org/archives 
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815 
----------------------------------------------------- 

______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2