Hi Wayne,
The good 'crater-like' solder attachment with brittle separation is characteristic of 'Black Pad.' My theory—totally unsupported by evidence other than they way these failures look like—is that somehow the p-concentration around the periphery is not as high.
Werner
-----Original Message-----
From: Thayer, Wayne - IIW <[log in to unmask]>
To: [log in to unmask]
Sent: Mon, Mar 1, 2010 8:55 am
Subject: Re: [TN] Hackneyed?
Hi Inge-
Just completed an emergency FA in another project, so I'm just tuning in.
Others asked about a cross-section. Did I miss your reply? Looking at the
grain structure and elemental analysis for the different zones of the joint
would probably help give us more insight.
Also, I haven't seen any theories on the variation in properties across the
joint (periphery looks great, but interior looks rotten). Has Werner given a
theory as to why that is?
You haven't suggested dismissing the theory that microvias have anything to do
with this phenomenon, yet I don't see evidence in your pix of any microvias, so
I presume the pix all came from pads which don't have microvias. Is that
correct?
I agree with Werner that I've seen overbaked joints do this. In any case, such
joints cause nightmares because they look nice (and are nice) on the outside.
Wayne
-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Werner Engelmaier
Sent: Saturday, February 27, 2010 11:01 AM
To: [log in to unmask]
Subject: Re: [TN] Hackneyed?
Hi Inge,
Yes, I have seen this before-not with those absolutely great pictures, but with
very similar elemental distributions.
In that case, the assembly saw nine (9!!!) soldering exposures.
I looks to me, your assembly was either exposed to soldering temperatures too
often and/or too long.
Werner
-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Inge
Sent: Wednesday, February 24, 2010 2:54 PM
To: [log in to unmask]
Subject: [TN] Hackneyed?
Hi Folks,
am asking you to sacrifice a minute on a topic that may make you sick, as
much as it has been discussed. Have a look at the SEM images that
(hopefully) will be beamed by our most honorable guy, Dr Gregory. By
order:
1. Pic 38 BGA ball after the preying off the 560 ball BGA from the board.
SEI mode.
http://stevezeva.homestead.com/files/XILINX_Daniel_38.jpg
2. pic 39, same at x 5,000
http://stevezeva.homestead.com/files/XILINX_Daniel_39.jpg
3. pic 40,samet at x 10,000
http://stevezeva.homestead.com/files/XILINX_Daniel_40.jpg
4.pic, 41 same at x 20,000
These four show the face of the pulled-off balls. The package/board was
sectioned into halv by half inch pieces with a thin blade diamond saw and
then each BGA section was separated from the board
by means of a steel.
http://stevezeva.homestead.com/files/XILINX_Daniel_41.jpg
After SEM 1-4 I made EDS, which can be seen below.
5. http://stevezeva.homestead.com/files/XILINX_Backlund_Ball_2.doc
As you can see, there is nearly no Lead (!), a high w/% Nickel, a little Tin
and lots of Phosphorous. Clearly, the separation has been in a
Now, continue with having a look at the board pads after the preying-off.
6. pic 44, Board pad at low magnification and SEI mode.
http://stevezeva.homestead.com/files/XILINX_Daniel_44.jpg
7.pic 46, same at x 5,000
http://stevezeva.homestead.com/files/XILINX_Daniel_46.jpg
8.pic 48, same at x 10,000
http://stevezeva.homestead.com/files/XILINX_Daniel_48.jpg
9. pic 50, same at x 20,000
http://stevezeva.homestead.com/files/XILINX_Daniel_50.jpg
10. pic 51, same but with BS mode
http://stevezeva.homestead.com/files/XILINX_Daniel_51.jpg
11. XILINX_backlund_pad_1.doc
http://stevezeva.homestead.com/files/XILINX_Backlund_Pad_1.doc
As you can see here, there is more Lead, a high w/% Nickell, much more Tin
and still lots of Phosphorous.
Discussion:
Obviously, real and reliable solder joints are only in the circumperipheric
of the whole (best understood with pic 10). How strong the adhesion was in
the main part of the joint, we don't know. From the function (final)
electrical testing, we have experienced several cases with disturbed
signals. Many a times, we have had to remove the BGA and supersede with a
fresh one. The test engineer told me, that by slightly add pressure to the
BGA, he may get the signal through again. He thinks we have an issue with
the uvias, others think there is a problem with the BGAs, myself I'm
committed to my theory that this has to do with the rotten interface between
the Tin/Lead and the ENIG pads.
Question:
Is anyone familiar with the said? What is your opinion about the
demonstrated solder joints? Can yoy get cracks and electrical misfunction,
despite that hundreds of balls are holding the BGA close to the board in a
'iron grip' ?
Wayne? Steve? Dave? George W? Vlad?
Thanks in advance. You'll have to wait for Steve to fix the exhibition.
/Inge
______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------
______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------
______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------
This e-mail and any files transmitted with it may be proprietary and are
intended solely for the use of the individual or entity to whom they are
addressed. If you have received this e-mail in error please notify the sender.
Please note that any views or opinions presented in this e-mail are solely those
of the author and do not necessarily represent those of ITT Corporation. The
recipient should check this e-mail and any attachments for the presence of
viruses. ITT accepts no liability for any damage caused by any virus transmitted
by this e-mail.
______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------
______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|