Inge,
I've been working on a similar project for a customer recently.  Ni is full of voids, not as spongy as yours, but weird (to me, I have no expertise in plating).  The surface is really rough.  Au measurements on the bare boards is proving very difficult.  FIB mill/SEM yields 1 microinch Au, microsection/SEM yields 2, XRF says 4-5.  Then 2nd pass reflow leaves Au behind, don't chalk all that Au up to the sputter.  We use Pt sputter just to be safe.

Your solderability problem may be simpler-  11% P

As for electrical malfunction, heck yes.  Although, usually only on the corner balls, unless the corner balls are cratering and the inward ball joints are cracked/non-wet.  We get a lot of these FAs because you can't see them except in the microsection.

Chris

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Hernefjord Ingemar
Sent: Thursday, February 25, 2010 3:09 AM
To: [log in to unmask]
Subject: Re: [TN] Hackneyed?

Sorry, missed to tell you all. Had to sputter some nanometers of Gold on the samples to avoid charging up when doing SEM. So, omit Gold.

Inge

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Rex Waygood
Sent: torsdag 25 februari 2010 08:59
To: [log in to unmask]
Subject: Re: [TN] Hackneyed?

I just sat and looked at your images and the documents.
Why are you seeing so much Gold on your pads?
That would not seem to be good.
Regards
Rex


Rex Waygood
Technical Manager
 
Hansatech EMS provides value manufacturing through engineering and quality
 
Hansatech EMS Limited
Benson Road
Nuffield Industrial Estate
Poole
Dorset
BH17 0RY
 
+44 (0)1202 338200



 

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Inge
Sent: 24 February 2010 19:54
To: [log in to unmask]
Subject: [TN] Hackneyed?

Hi Folks,

am asking you to sacrifice  a minute on a topic that may make you sick, as much as it has been discussed. Have a look at the SEM images that
(hopefully) will be beamed by our most honorable guy,  Dr Gregory.  By
order:

1. Pic 38 BGA ball after the preying off the 560 ball BGA from the board. 
SEI mode.
2. pic 39,  same at x 5,000
3. pic 40,samet at x 10,000
4.pic, 41 same at x 20,000
These four show the face of the pulled-off balls. The package/board was sectioned into halv by half inch pieces with a thin blade diamond saw and then each BGA section was separated from the board by means of a steel. 
After SEM 1-4 I made EDS, which can be seen below.
5. XILINX_backlund_ball_2.doc
As you can see, there is nearly no Lead (!), a high w/% Nickel, a little Tin and lots of Phosphorous. Clearly, the separation has been in a Sn/Ni/P-layer.


Now, continue with having a look at the board pads after the preying-off.
6. pic 44, Board pad at low magnification and SEI mode.
7.pic 46,  same at x 5,000
8.pic 48, same at x 10,000
9. pic 50, same at x 20,000
10. pic 51, same but with BS mode
11. XILINX_backlund_pad_1.doc
As you can see here, there is more Lead, a high w/% Nickell, much more Tin and still lots of Phosphorous.


Discussion:
Obviously,  real and reliable solder joints are only in the circumperipheric of the whole (best understood with pic 10).  How strong the adhesion was in the main part of the joint, we don't know.  From the function (final) electrical testing, we have experienced several cases with disturbed signals.  Many a times, we have had to remove the BGA and supersede with a fresh one. The test engineer told me, that by slightly add pressure to the BGA, he may get the signal through again.  He thinks we have an issue with the uvias, others think there is a problem with the BGAs, myself I'm committed to my theory that this has to do with the rotten interface between the Tin/Lead and the ENIG pads.

Question:
Is anyone familiar with the said?  What is your opinion  about the demonstrated solder joints? Can yoy get cracks and electrical misfunction, despite that hundreds of balls are holding the BGA close to the board in a 'iron grip' ?

Wayne? Steve? Dave? George W? Vlad?

Thanks in advance.  You'll have to wait for Steve to fix the exhibition.

/Inge
 


______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] ______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0 To unsubscribe, send a message to [log in to unmask] with following text in the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------

______________________________________________________________________
This email has been scanned by the MessageLabs Email

______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] ______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0 To unsubscribe, send a message to [log in to unmask] with following text in the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest Search the archives of previous posts at: http://listserv.ipc.org/archives Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2