Dear all
I'd like to have your opinion about the interpretation of the IPC-6012.
A multilayer is sequentially built and has a (pre-drilled and plated)
core for layers 1 and 2.
This core is not laser drillable and can be only mechanically drilled.
Table 3-3 applies to Through Holes, Blind and Buried Vias > 2 layers.
What about blind vias equal to 2 layers? (Such as layer 1-2 made of a
drilled and plated core). Table 3-5 applies to a 2 layers core, but is
defined as a buried core only.
Note 1 to table 3-3 : "Does not apply to microvias. Blind vias have
greater than 1:1 aspect ratio ."
Note 1 to table 3-4 :" Microvias are defined as less or equal to 1:1
aspect ratio ( excludes mechanical drill), or mechanically drilled <_
0.15 mm."
Which standard shall apply to blind vias that have an aspect ratio less
or equal to 1:1 - for example layer 1-2 made of a drilled and plated
core :
Case A : 0.25 mm thick core with 0.25 mm mechanically drilled holes .
Case B : 0.25 mm thick core with 0.20 mm mechanically drilled holes.
Just to compare: what is your opinion for the copper needed for a
double sided PCB with filled vias