We're quoting a Rigid Flex design that requires scoring for de-panalization. We
typically use breakaway tabs but the CM is insisting on scoring.
It's a 6 layer rigid with 2 layers of flex, 0.062" thick, balanced build. Flex is a
DuPont AP8525 with FR0110 covers.
Our scoring service bureau has indicated that they can run the job by
performing a deeper score from one side that will cut through the flex and a
shallow score from the other leaving the web offset.
Our past experiance (2 years ago) with scoring through flex was problematic.
Is this a process common and or doable and are there any other issues to be
addressed / concerned about?
Thanks
Paul Tome'
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------