Pete,

I agree. I wanted to know if Bills calculator would work on thermo
reliefs and could it be compared to the accuracy of the current formula.

After re-reading Bills original email I realize I may have
misunderstood, and the formula is for one via attached to nothing vs. a
via attached to a plane or copper pour.

Bill,

I guess you are not the only one who got busted in the assumption
department.

Thanks,

Ted T.

-----Original Message-----
From: Pete Houwen [mailto:[log in to unmask]] 
Sent: Wednesday, January 06, 2010 8:16 AM
To: [log in to unmask]; Tontis, Theodore
Subject: Re: Thermally Conductive & Plated Via Fill

Ted,

I doubt anyone has done the math on that, because you would be answering

two completely opposite questions.  Thermal relief holes are intended to

impede thermal transfer, thermal conducting holes aid thermal transfer.
So 
the question is, do you want that hole to conduct heat or not?  And if
you 
don't care, use a solid connection for better connectivity of the plane.


Pete

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2