TECHNET Archives

January 2010

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
John Goulet <[log in to unmask]>
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, [log in to unmask]
Date:
Sat, 16 Jan 2010 16:44:13 +0000
Content-Type:
text/plain
Parts/Attachments:
text/plain (221 lines)
I generated the conceptual design for a batch cleaner and then Kyzen in Manchester NH generated the final design. We purchased several units for several of our manufacturing facilities after having successfully used the first two in our NH facility for several years. The spray under immersion cleaning system allows us to clean a batch of boards every 10 minutes and this system eliminated the issues listed in these E-mails related to ultrasonic cleaners. 

The batch cleaner using a saponifer allows cleaning under micro BGAs and to clean boards that are going to be conformal coated. 

The batch cleaner can be used to deflux under micro BGAs in production or after replacement for No-Clean flux that can cause signal integrity issues  when in the gigaHz range due to capacitance from flux residues. The boards have to be immediately washed in the aqueous cleaner to remove all the saponifer. Obviously this work is done prior to placing switches, speakers etc that are not aqueous compatible. 

    John Goulet 

   Sr Process Engineer 


----- Original Message ----- 
From: "Gregg Owens" <[log in to unmask]> 
To: [log in to unmask] 
Sent: Friday, January 8, 2010 11:54:55 AM GMT -05:00 US/Canada Eastern 
Subject: Re: [TN] ULtrasonic Cleaning of PCBAs 

Have to say a big thank you to TechNet! Your thoughts have been passed onto the appropriate engineers. All I can say is you make me look smart knowing the right people to contact. So you have all started my 2010 in a very nice way.... 8-{)} 

Gregg Owens 
Technical Writer - Avionics 
Space Exploration Technologies Corporation 

-----Original Message----- 
From: Dean Stadem [mailto:[log in to unmask]] 
Sent: Friday, January 08, 2010 7:59 AM 
To: 'TechNet E-Mail Forum'; 'Steven Creswick'; Gregg Owens 
Subject: RE: [TN] ULtrasonic Cleaning of PCBAs 

Ta-da! 
Ain't I a great resource, or what? 
http://www.kandus.com/Configurations/33852%20Branson%208K.html 


R. Dean Stadem 
Consulting Engineer 
Analog Technologies Corp./Lumagine, Inc. 
11441 Rupp Drive 
Burnsville, MN 55431 
(952)894-9228 
[log in to unmask] 


-----Original Message----- 
From: TechNet [mailto:[log in to unmask]] On Behalf Of Steven Creswick 
Sent: Thursday, January 07, 2010 12:57 PM 
To: [log in to unmask] 
Subject: Re: [TN] ULtrasonic Cleaning of PCBAs 

Mark, 

Whole heartedly agree!  Aluminum is even worse/quicker in cavity/open 
packages. 

The variable sweep freq transducers that Richard references have helped 
tremendously.  I still proceed cautiously, however. 

Steve C 

-----Original Message----- 
From: TechNet [mailto:[log in to unmask]] On Behalf Of Woolley, Mark D. 
(Mark) 
Sent: Thursday, January 07, 2010 10:27 AM 
To: [log in to unmask] 
Subject: Re: [TN] ULtrasonic Cleaning of PCBAs 

Ultrasonic action can damage bondwired in OPEN PACKAGES, meaning metal 
cans etc.  The gold wires are quickly work hardened by the movement and 
become brittle.  That is not an issue with plastic encapsulated 
components, because the bondwires need to be able to vibrate freely. 

mark 


mark 
Mark Woolley 

-----Original Message----- 
From: TechNet [mailto:[log in to unmask]] On Behalf Of Guy Ramsey 
Sent: Thursday, January 07, 2010 8:20 AM 
To: [log in to unmask] 
Subject: Re: [TN] ULtrasonic Cleaning of PCBAs 

The company I worked for during the 1990's used Crest Ultrasonic 
cleaning 
equipment. The electronic manufacturing process methods were originally 
designed by experts from Rockwell International in the late 1970s and 
early 
1980s. The products carried a 10 year warranty. 
I was their Quality Manager. I tracked electronic failure data through 
collected over 30 years. 
There were only two instance of failures induced by Ultrasonic cleaning, 
both related to a failure of the amplifiers which caused the transducers 
to 
output too much energy. This damaged reed switches and reed relays. 
These 
were not latent failures. 

Guy 

-----Original Message----- 
From: TechNet [mailto:[log in to unmask]] On Behalf Of Gregg Owens 
Sent: Thursday, January 07, 2010 2:28 AM 
To: [log in to unmask] 
Subject: [TN] ULtrasonic Cleaning of PCBAs 

Dear Technetters: 

I have been posed a question that I don't have much experience with 
other 
than general knowledge. It there an ultrasonic cleaner system/setting 
available that can clean printed circuit assemblies (yes will electronic 
components)?  With some pending designs there is a concern that our 
board 
houses will be able to sufficiently clean (deflux) under bottom only 
components/BGA style components. I know from the standards that 
ultrasonic 
cleaning is typically limited to bare boards so as to not damage 
internal 
interconnections/wire bonds. But I am wondering if there is a low 
setting 
available to agitate the solution while not destroy/damage components? 

Your thoughts are most appreciated. 

Gregg Owens 
Technical Writer - Avionics 
Space Exploration Technologies Corporation 
1 Rocket Road | Hawthorne | CA | 90250 
[log in to unmask] 

--------------------------------------------------- 
Technet Mail List provided as a service by IPC using LISTSERV 15.0 
To unsubscribe, send a message to [log in to unmask] with following text 
in 
the BODY (NOT the subject field): SIGNOFF Technet 
To temporarily halt or (re-start) delivery of Technet send e-mail to 
[log in to unmask]: SET Technet NOMAIL or (MAIL) 
To receive ONE mailing per day of all the posts: send e-mail to 
[log in to unmask]: SET Technet Digest 
Search the archives of previous posts at: 
http://listserv.ipc.org/archives 
Please visit IPC web site 
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 
for additional information, or contact Keach Sasamori at [log in to unmask] 
or 
847-615-7100 ext.2815 
----------------------------------------------------- 

--------------------------------------------------- 
Technet Mail List provided as a service by IPC using LISTSERV 15.0 
To unsubscribe, send a message to [log in to unmask] with following text 
in 
the BODY (NOT the subject field): SIGNOFF Technet 
To temporarily halt or (re-start) delivery of Technet send e-mail to 
[log in to unmask]: SET Technet NOMAIL or (MAIL) 
To receive ONE mailing per day of all the posts: send e-mail to 
[log in to unmask]: SET Technet Digest 
Search the archives of previous posts at: 
http://listserv.ipc.org/archives 
Please visit IPC web site 
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional 
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 
ext.2815 
----------------------------------------------------- 

--------------------------------------------------- 
Technet Mail List provided as a service by IPC using LISTSERV 15.0 
To unsubscribe, send a message to [log in to unmask] with following text 
in 
the BODY (NOT the subject field): SIGNOFF Technet 
To temporarily halt or (re-start) delivery of Technet send e-mail to 
[log in to unmask]: SET Technet NOMAIL or (MAIL) 
To receive ONE mailing per day of all the posts: send e-mail to 
[log in to unmask]: SET Technet Digest 
Search the archives of previous posts at: 
http://listserv.ipc.org/archives 
Please visit IPC web site 
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 
for additional information, or contact Keach Sasamori at [log in to unmask] 
or 
847-615-7100 ext.2815 
----------------------------------------------------- 

--------------------------------------------------- 
Technet Mail List provided as a service by IPC using LISTSERV 15.0 
To unsubscribe, send a message to [log in to unmask] with following text 
in 
the BODY (NOT the subject field): SIGNOFF Technet 
To temporarily halt or (re-start) delivery of Technet send e-mail to 
[log in to unmask]: SET Technet NOMAIL or (MAIL) 
To receive ONE mailing per day of all the posts: send e-mail to 
[log in to unmask]: SET Technet Digest 
Search the archives of previous posts at: 
http://listserv.ipc.org/archives 
Please visit IPC web site 
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional 
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 
ext.2815 
----------------------------------------------------- 

--------------------------------------------------- 
Technet Mail List provided as a service by IPC using LISTSERV 15.0 
To unsubscribe, send a message to [log in to unmask] with following text in 
the BODY (NOT the subject field): SIGNOFF Technet 
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL) 
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest 
Search the archives of previous posts at: http://listserv.ipc.org/archives 
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815 
----------------------------------------------------- 

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2