Hi Shawn,

I've seen "SIT" used in the past standing for "Select In Test". This would
be for a part that is not installed until test where they need to select a
certain value to make it work. This is accompanied with a note at the bottom
of the parts list saying what parts are authorized to use.

KennyB

-----Original Message-----
From: Upton, Shawn [mailto:[log in to unmask]] 
Sent: Tuesday, December 08, 2009 7:36 AM
To: [log in to unmask]
Subject: [TN] PCB parts that are not installed

Quick question: What is the best method of specifying parts that are not
installed on a PCB assembly?  I've used "DNI" for a while, while others
have used "TBD" or "DNK" (for Do Not Kit).  "TBD" was used for locations
which would be stuffed after some testing--maybe 1.01k had to be used on
this assembly, 1.05k on another, etc.

What is typical method on this?  For parts that are intentionally not
installed, and parts that may be installed at a later date.

Also, just to verify: is it generally desirably to list all parts that
are not installed on a board?  I usually list all parts, installed or
not, and the parts not installed are specifically listed as "Do Not
Install", so as to make it clear that they are DNI'd.

Shawn Upton, KB1CKT
Test Engineer
Allegro MicroSystems, Inc
[log in to unmask]
603.626.2429/fax: 603.641.5336


---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2