I agree with Steve and the rest but I have one caveat....

If you use PEM specs for design, you must use PEM parts...

PEM-type parts are different then PEM parts, even the PEM knockoffs are different...

Every time you use a PEM-type part in a PCB you will have problems...

Switch to actual PEM parts and the problem seems to go away...

Paul

Paul Edwards
Surface Art Engineering


-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Steve Smith
Sent: Friday, November 06, 2009 11:41 AM
To: [log in to unmask]
Subject: Re: [TN] PEM (rivets) in PCB - Found word(s) list error in the Text body

We have used PEM standoffs, studs and nuts in pc boards, sheet metal, and copper bus bars for years.  I can think of only one assembly house having any problem with the pc board mount type and that was because they didn't install them as recommended by PEM.  As Lenny Carter said, if you use them as intended you should have no problems.

My regards,
Steve Smith
Project Engineer
Staco Energy Products Co.
"Your tailored power solutions provider"
Web Site: www.stacoenergy.com



DISCLAIMER AND/OR CONFIDENTIALITY NOTICE:
This message, including any attached materials, is intended solely for the use of the individual or entity to whom it is addressed and may contain information that is privileged, confidential, and exempt from disclosure under applicable law. If the reader of this electronic mail transmission is not the intended recipient, you are hereby notified that any dissemination, distribution, or copying of this communication is strictly prohibited. If you have received this communication in error, please e-mail or call Staco Energy Products Co. at (937) 253-1191. Thank you for your cooperation


-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Lenny Carter
Sent: Friday, November 06, 2009 2:23 PM
To: [log in to unmask]
Subject: Re: [TN] PEM (rivets) in PCB

There are specific PEMS designed for pcb materials, in differing thicknesses.  See their website at www.pemnet.com.  If you are having the assembly made by a CM, you  may want to discuss your requirement with them, as they may have their own guidelines.  I have used many PEMs over the years, in FR4, aluminum enclosures, and other various composites.  I have always had surprisingly good results when they are used as intended and installed correctly.  You may have a significant component "keep out" for tooling and pcb stresses, depending on your application.  good luck.  Lenny ERG


----- Original Message -----
From: "henry rekers" <[log in to unmask]>
To: <[log in to unmask]>
Sent: Friday, November 06, 2009 1:54 PM
Subject: [TN] PEM (rivets) in PCB


Is anybody out there aware of any spec/inspection criteria/documentation on how to specify/design/inspect Pem type fasteners?

We have a design that may require this, but I'm not willing to commit until I have some more background info. Specifically, is this a normal process for a board shop? Are there any 'gotcha's'?

Thanks.


      __________________________________________________________________
Yahoo! Canada Toolbar: Search from anywhere on the web, and bookmark your favourite sites. Download it now http://ca.toolbar.yahoo.com.

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0 To unsubscribe, send a message to [log in to unmask] with following text in the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0 To unsubscribe, send a message to [log in to unmask] with following text in the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest Search the archives of previous posts at: http://listserv.ipc.org/archives Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0 To unsubscribe, send a message to [log in to unmask] with following text in the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest Search the archives of previous posts at: http://listserv.ipc.org/archives Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------


==============================================================================

This email and any attachments thereto may contain private, confidential, and
privileged material for the sole use of the intended recipient. Any review, copying,
or distribution of this email (or any attachments thereto) by others is strictly prohibited.
If you are not the intended recipient, please contact [log in to unmask]
immediately and permanently delete the original and any copies of this email and
any attachments thereto. 

==============================================================================


---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2