Gregg,

 If I had gone a little further and read the entire email issue I would have
kept quite. :-(

Thanks,
Bob Kondner

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Temkin, Gregg
Sent: Thursday, November 12, 2009 10:22 AM
To: [log in to unmask]
Subject: Re: [TN] Handling of SMT reeled components

I don't think you get "hermetic" sealing with cover tape and as far as I
hermetic sealing doesn't play into ESD shielding performance.

Also, "antistatic" doesn't equate with shielding or Faraday cage.

Gregg

-----Original Message-----
From: Reuven Rokah [mailto:[log in to unmask]] 
Sent: Thursday, November 12, 2009 6:55 AM
To: [log in to unmask]
Subject: Re: [TN] Handling of SMT reeled components

If it hermetic sealed and packaged as a Faraday package, and unless it is
not opened, you can hold / handled it without wrist straps

Best Regards

Reuven ROKAH 
e mail: [log in to unmask]
??Think green before printing this mail... Thanks

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Gervascio, Thomas L
Sent: Thursday, November 12, 2009 3:44 PM
To: [log in to unmask]
Subject: [TN] Handling of SMT reeled components

We have parts in antistatic reels and sealed with antistatic cover tape. Do
we need to handle with wriststraps or would this suffice as a Faraday cage?

Tom Gervascio




---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2