John et.al. - I may be repeating what has already been stated.

We have always allowed cracks/voids in zone A (3.6.2.3/4) - eyebrows. As
can been seen from the response this is a common occurrence.

If in zone B they have been treated as cracks/voids per 3.6.2.3/4





Jim

-----Original Message-----
From: IPC-600-6012 [mailto:[log in to unmask]] On Behalf Of John Perry
Sent: Monday, November 09, 2009 10:52 AM
To: [log in to unmask]
Subject: [IPC-600-6012] Double-Blind Via Construction and IPC-6012C

Hello Everyone,

Recently, we updated the attached IPC-6012C Figure 3-9 to better
illustrate requirements for laminate anomalies in Zone A and Zone B.

A question has come up regarding laminate anomalies in double-blind via
constructions.  Please refer to the attached PowerPoint file.  The
questions are:


*         Are laminate defects in Zone A allowed after thermal stress?

*         Are any defects allowed in the non-thermal stressed condition
in Zone A?

*         What would be the size of defects allowed?  Would they be the
same as for standard PTHs?

*         If defects allowed in non-stressed condition is there a
minimum spacing requirement of resin/glass between layers?

Let's discuss this through this IPC-600-6012 e-mail forum and see if
there is a need to further update IPC-6012C Figure 3-9 (or duplicate it
and modify as needed for double-blind constructions).

Regards,

John Perry
Technical Project Manager
IPC - Association Connecting Electronics Industries(r)
3000 Lakeside Drive # 309S
Bannockburn, IL 60015-1249 USA
+1 847-597-2818 (tel)
+1 847-615-7105 (fax)
+1 847-615-7100 (Main)
[log in to unmask]
www.ipc.org



NOTICE:  This email message is for the sole use of the intended recipient(s) and may contain confidential and privileged information.  Any unauthorized review, use, disclosure or distribution is prohibited.  If you are not the intended recipient, please contact the sender by reply email and destroy all copies of the original message.

ATOM RSS1 RSS2