In theory you can ask for as much as you like, but 1.5 mil is about the
most. It is also better define 1.5mil as average minimum rather than
absoulate minimum. Anything more than that will cause other process issues. 

Completely fill a via with copper plating is possible but only handful of
suppliers do it and it cost $$$$$$.

Regards,

Jason

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of SUBSCRIBE
DesignerCouncil wheels
Sent: Thursday, October 29, 2009 7:44 AM
To: [log in to unmask]
Subject: Re: [TN] Via fill for heat transfer

I see that extra copper plating sounds like a better way to go. What is a 
typical amount that a fab house can plated a via up to?

Would it be bad idea to complete fill a via with copper plating?

John W

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2