A conventional mechanical breaker does not have that problem. Even breaking 
400,000 Volts can be done without that extra energy, but it may be little 
ionizing issues.

http://www.youtube.com/watch?v=hIkNY5xjy5k&feature=related

/Inge



----- Original Message ----- 
From: "Thayer, Wayne - IIW" <[log in to unmask]>
To: <[log in to unmask]>
Sent: Wednesday, October 28, 2009 10:59 PM
Subject: Re: [TN] Looking for a way to fuse a 20 milliamp wire


Quite true.  It's a simple matter of energy conservation--it takes energy to 
break a wire!  And when you are talking about a few milliamps the voltage 
drop would have to be large to provide this energy.

Look into a smart circuit breaker like Inge is suggesting.

Another possibility might be a positive temperature coefficient 
thermistor--the resistance increases linearly with temperature, so it will 
tend to cause the current to drop, regulating the load current.  I don't 
know if one is available with the characteristics you might need.

Wayne Thayer

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Inge
Sent: Wednesday, October 28, 2009 5:41 PM
To: [log in to unmask]
Subject: Re: [TN] Looking for a way to fuse a 20 milliamp wire

Evev a tiny tin whisker is to coarse, and a 1 mil bond wire will need amps 
to break. You need a cmos switch.
/Inge


----- Original Message -----
From: "Robert Kondner" <[log in to unmask]>
To: <[log in to unmask]>
Sent: Wednesday, October 28, 2009 10:24 PM
Subject: Re: [TN] Looking for a way to fuse a 20 milliamp wire


> Hi,
>
>  How fast and why not use a circuit?
>
>  I would guess it does not need to break 10K Amps at 250VAC. How much
> resistance can you tolerate?
>
> Bob Kondner
>
> -----Original Message-----
> From: TechNet [mailto:[log in to unmask]] On Behalf Of Barbara Burcham
> Sent: Wednesday, October 28, 2009 4:51 PM
> To: [log in to unmask]
> Subject: [TN] Looking for a way to fuse a 20 milliamp wire
>
> Hey Y'all,
> I am fishing for ideas here...
> I have a need a fuse that would blow at 2 milAmps current.
> A part?
> A trace?
> A tiny wire?
> Any ideas?
>
> Thanks,
> Barbara
>
>
> Barbara Burcham, C.I.D.
>
> *pcb* Trace Design
>
> 1022 Plantation Drive
>
> Richmond, TX 77406
>
> [log in to unmask]
>
> 281-341-7539
>
> 713-249-7718 Cell
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 15.0
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to
> [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/archives
> Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
> for additional information, or contact Keach Sasamori at [log in to unmask] or
> 847-615-7100 ext.2815
> -----------------------------------------------------
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 15.0
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to
> [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/archives
> Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
> for additional information, or contact Keach Sasamori at [log in to unmask] or
> 847-615-7100 ext.2815
> -----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to 
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to 
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 
for additional information, or contact Keach Sasamori at [log in to unmask] or 
847-615-7100 ext.2815
-----------------------------------------------------

This e-mail and any files transmitted with it may be proprietary and are 
intended solely for the use of the individual or entity to whom they are 
addressed. If you have received this e-mail in error please notify the 
sender.
Please note that any views or opinions presented in this e-mail are solely 
those of the author and do not necessarily represent those of ITT 
Corporation. The recipient should check this e-mail and any attachments for 
the presence of viruses. ITT accepts no liability for any damage caused by 
any virus transmitted by this e-mail.

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to 
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to 
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 
for additional information, or contact Keach Sasamori at [log in to unmask] or 
847-615-7100 ext.2815
----------------------------------------------------- 

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2