Kevin,

We use a Fischer Technology XRF and routinely measure immersion silver thickness in this range without any special calibration.

Regards,

George

George M. Wenger

Andrew Wireless Solutions

Senior Principal FMA / Reliability Engineer

40 Technology Drive, Warren, NJ 07059

(908) 546-4531 [Office]  (732) 309-8964 [Mobile]

[log in to unmask]


-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Glidden, Kevin
Sent: Friday, October 23, 2009 3:52 PM
To: [log in to unmask]
Subject: [TN] Measurement of ImAg plating thickness using XRF

Late on Friday I know, so I'll re-visit this one on Monday, but I am looking for someone who can verify ImAg plating thickness in the range of 5 to 12 micro-inches applied over copper using XRF techniques.  The IPC-4553 specification indicates this might be more difficult to achieve for silver than for other finishes, and requires some specialized equipment and calibration methods.  I am looking to have this done on 1-2 PCBs only.  Offline responses / quotes are OK.

Thank you


Kevin Glidden
Manufacturing Engineer
Luminescent Systems Inc.
4 Lucent Drive
Lebanon, NH 03766
(603) 643-7766 x3152

Please note, LSI now operates on a 9/80 work schedule, and is closed on alternating Fridays.  Please click the link provided to view the days LSI will be closed.
http://www.astronicslsi.com/contact/contact.asp

NOTICE: This communication is intended specifically for the recipient(s) named above and may include proprietary, confidential or privileged information. If you are not a named recipient, you should immediately delete or destroy all electronic and physical copies of this communication. Unintended recipients also should not utilize, repeat, publish or relay to any other person the information contained herein nor should they take any action based upon, in whole or in part, such information. If you have received this message in error, you are requested to contact the sender immediately.

EXPORT COMPLIANCE STATEMENT: The information contained herein is or may be controlled by the International Traffic in Arms Regulations (ITAR), 22 CFR 120-130, or the Export Administration Regulations (EAR) and may not be exported, or disclosed to a foreign person, whether in the United States or abroad, without prior U.S. Government and Astronics Luminescent Systems written approval. Violations of these regulations could result in administrative, civil or criminal penalties.  If you have any questions about the nature of the material contained in this email please contact the sender immediately.


---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2