 Hi Vladimir,

Then we are not communicating.

Please explain to me what YOU mean by 'BP failure'.

When I say 'BP failure', I mean it is because too much P between the Ni and the IMC layers has weakened the bond leading to brittle separation on sufficient loading. I do not differentiate as to the cause(s) for too much P. For me they describe a damage mechanism.

You can similar appearance with too much and too little P.

Werner





 





 



-----Original Message-----

From: [log in to unmask]

To: Werner Engelmaier <[log in to unmask]>; [log in to unmask]

Sent: Tue, Oct 20, 2009 10:44 pm

Subject: Re: [TN] ENIG Issue












   Werner,



You just confirmed what I said in my previous e-mail. You customer got failure with black appeared pads, but it wasn't BP failure. Similar appearance doesn't mean the same mechanism.



Regards,



Vladimir

SENTEC

11 Canadian Road, Unit 7.

Scarborough, ON M1R 5G1

Tel: (416) 899-1882

Fax: (905) 882-8812

www.sentec.ca







From:  Werner Engelmaier <[log in to unmask]>




Date: Tue, 20 Oct 2009 22:16:40 -0400



To: <[log in to unmask]>; <[log in to unmask]>



Subject: Re: [TN] ENIG Issue










 Hi Vladimir,


I have one client who experienced 'Black Pad' after 9(!) soldering operations. The P-content got progressively worse; it peaked with the EDS spikes for P being as high as those for Sn.


Werner








 








 





-----Original Message-----


From: [log in to unmask]


To: TechNet E-Mail Forum <[log in to unmask]>; Werner Engelmaier <[log in to unmask]>


Sent: Tue, Oct 20, 2009 10:07 pm


Subject: Re: [TN] ENIG Issue
















Werner,







With all due respect, I don't think you are right.







Regards,







Vladimir



SENTEC



11 Canadian Road, Unit 7.



Scarborough, ON M1R 5G1



Tel: (416) 899-1882



Fax: (905) 882-8812



www.sentec.ca











-----Original Message-----



From: Werner Engelmaier <[log in to unmask]>



Date:         Tue, 20 Oct 2009 22:01:35 



To: <[log in to unmask]>



Subject: Re: [TN] ENIG Issue







 Hi George,



\While what you say in the first paragraph is correct, the second paragraph is 



not.



'Black Pad' is not an all-or-nothing proposition. The seeds are sown at the 



Ni-plating (not the Au-plating) with the P-codeposition. However, multiple or 



lengthy expositions to high soldering temperatures result in more Ni being 



dissolved to form IMCs leaving ever more P behind. This can create 'Black Pad' 



where none existed before.



Werner











 











 







-----Original Message-----



From: George Milad <[log in to unmask]>



To: [log in to unmask]



Sent: Tue, Oct 20, 2009 9:52 pm



Subject: Re: [TN] ENIG Issue











































As always as soon as there is a solderability issue with ENIG, "Black pad"  



comes up. This is a problem because it does not allow for further 



investigation.  Everyone accepts since this is ENIG then it must be black pad.



 



If this was a black pad issue the back side should have exhibited the same  



problem. BP occurs during the plating of the gold on top of the Ni. BP 



cannot  differentiate one side from the other.



 



Do not accept BP as the answer and keep investigating.



 



 



Regards



George Milad



George Milad



National Accounts  Manager for Technology



Uyemura International Corp (UIC)



249 Town Line Rd  



Southington CT 06489



[log in to unmask]



Cell: (516) 901  3874







---------------------------------------------------



Technet Mail List provided as a service by IPC using LISTSERV 15.0



To unsubscribe, send a message to [log in to unmask] with following text in



the BODY (NOT the subject field): SIGNOFF Technet



To temporarily halt or (re-start) delivery of Technet send e-mail to 



[log in to unmask]: SET Technet NOMAIL or (MAIL)



To receive ONE mailing per day of all the posts: send e-mail to 



[log in to unmask]: SET Technet Digest



Search the archives of previous posts at: http://listserv.ipc.org/archives



Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for 



additional information, or contact Keach Sasamori at [log in to unmask] or 



847-615-7100 ext.2815



-----------------------------------------------------















 











---------------------------------------------------



Technet Mail List provided as a service by IPC using LISTSERV 15.0



To unsubscribe, send a message to [log in to unmask] with following text in



the BODY (NOT the subject field): SIGNOFF Technet



To temporarily halt or (re-start) delivery of Technet send e-mail to 



[log in to unmask]: SET Technet NOMAIL or (MAIL)



To receive ONE mailing per day of all the posts: send e-mail to 



[log in to unmask]: SET Technet Digest



Search the archives of previous posts at: http://listserv.ipc.org/archives



Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for 



additional information, or contact Keach Sasamori at [log in to unmask] or 



847-615-7100 ext.2815



-----------------------------------------------------












 





 



---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2