you're thinking too hard.
A cross-section of via and voided solder joint will tell the story.
At 04:06 AM 10/13/2009, Douglas McCall wrote:
>Hi,
>We have non-conductive resin filled and capped
>micro-via (via-in-pad) through the complete PWB
>thickness (1.6mm FR4) 8-layer, we have seen
>considerable voiding in the BGA balls following assembly:
>
>Q1) What is the chance of out-gassing from the
>PWB board (or specifically the filled capped
>via) going into the BGA ball and creating a void during reflow.
>
>Q2) What is adequate flatness on the PWB surface
>considering “dish-down” of the filled resin
>during via filling and before Cu plating. I
>think the IPC spec. is 70% but does anyone have differing experience of this.
>
>Q3) Would a fairly “rough” topology on the
>surface of the capping plating (i.e. not totally
>flat, bumps etc) cause any difference in the solderability,
>
>I believe that:
>· The via drilled diameter is 0.25mm
>· PWB finish ENIG,
>· Cu/Ni/Au plating thickness is 20um
>· The PWB thickness is 1.6mm
>· The PWB Tg is approx 170 deg-C
>· The paste is Pb-free,
>· The reflow profile is good to the
>paste suppliers recommended profile,
>· The PWB’s have been baked-out 130 deg-c 24-hours before assembly,
>· Reflow peak reached 242 deg-C
>· Reflow soak 170 deg-C for 170 seconds,
>
>There are large and small voids in the BGA balls
>during X-Ray and cross sectioning. Some of the
>BGA balls apear slightly elongated not correct shape.
>
>In essence would you think that it would be a PWB issue or assembly problem.
>
>Any feedback would be much appreciated.
>
>Thanks,
>D. McCall.
>mailto:
>[log in to unmask]
>_________________________________________________________________
>Save time by using Hotmail to access your other
>email accounts. http://clk.atdmt.com/UKM/go/167688463/direct/01/
>---------------------------------------------------
>Technet Mail List provided as a service by IPC using LISTSERV 15.0
>To unsubscribe, send a message to [log in to unmask] with following text in
>the BODY (NOT the subject field): SIGNOFF Technet
>To temporarily halt or (re-start) delivery of
>Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
>To receive ONE mailing per day of all the posts:
>send e-mail to [log in to unmask]: SET Technet Digest
>Search the archives of previous posts at: http://listserv.ipc.org/archives
>Please visit IPC web site
>http://www.ipc.org/contentpage.asp?Pageid=4.3.16
>for additional information, or contact Keach
>Sasamori at [log in to unmask] or 847-615-7100 ext.2815
>-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|