Hi Gregg,
It all DEPENDS. If the staking compound creates a stress concentration, operating T's could fall below about -20C, and the modulus of the staking compound is high, it could cause earlier failures.
Is it likely, not very.
Werner
-----Original Message-----
From: Gregg Owens <[log in to unmask]>
To: [log in to unmask]
Sent: Mon, Sep 28, 2009 4:58 pm
Subject: [TN] Component Staking
Hello all,
It's good to be back on TechNet once again. I have a question I could directly
answer so I thought I would put it out to the friendly experts of TechNet.
After soldering and during the component staking process some adhesive has
migrated onto adjacent solder connections and land areas. Could this become
detrimental in a high vibration environment? I know from 610 and 001 that
adhesive shall not contaminate the creation of the solder connection. However
this is AFTER the soldering process is complete would this be a concern?
Any thoughts? Thanks in advance,
Gregg Owens, CIT
Technical Writer - Avionics
Space Exploration Technologies
1 Rocket Road | Hawthorne | CA | 90250
310-363-6000
[log in to unmask]
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|