Thanks, Werner.

I think I understand this a little better. If the soldermask-defined pad does not allow the solder to flow down around the sides of the pad, but rather induces a stress riser where the BGA solderball meets the top of the pad, the stress is focused at the point where the solder contacts the pad, at the top of the pad. Therefore it is easier for the crack to form as opposed to a solder ball that is "anchored" with the pad fully embedded inside the solder ball. So the CTE-induced stresses are not from the mask, but the CTE delta between the BGA package and the substrate. Being that this stress riser is circumferential around the point where the solder makes contact with the pad, the initiation point and the direction of the crack propagation can be anywhere and go in any direction. Is that correct?



-----Original Message-----

From: TechNet [mailto:[log in to unmask]] On Behalf Of Werner Engelmaier /*

Sent: Thursday, September 17, 2009 1:22 PM

To: [log in to unmask]

Subject: Re: [TN] fractured SJs due to soldermask compression





 Hi Dean,

Let us be clear about this.

If you have soldermask-defined pads (SMDs), what results is solder joints with geometries defined by that solder mask. These geometries cause stress concentrations which typically will cause cycles-to-failure to be cut by about half. It has nothing to do with CTE expansion and contraction of the solder mask—unless, you do solder mask repair after assembly (!?) and the solder mask fills the space between component and PCB.

Werner





 





 



-----Original Message-----

From: Stadem, Richard D. <[log in to unmask]>

To: [log in to unmask]; [log in to unmask]

Sent: Thu, Sep 17, 2009 1:49 pm

Subject: RE: [TN] fractured SJs due to soldermask compression





















Werner, 

What I am trying to say is that issues of ground plane configuration will 

probably not lead to a reliability issue directly, unless they cause issues 

during reflow of the BGA. But if the ground pour is done using 

soldermask-defined pads, the soldermask-defined pads can lead to premature 

failure of the SJ. My understanding (gained from a direct question I asked you 

in your class) was that the soldermask can constrict the solder during CTE 

expansion and contraction. Did I not understand you correctly?



-----Original Message-----

From: TechNet [mailto:[log in to unmask]] On Behalf Of Werner Engelmaier /*

Sent: Thursday, September 17, 2009 12:32 PM

To: [log in to unmask]

Subject: Re: [TN] fractured SJs due to soldermask compression





 Hi Chris,

First, never heard of "fractured SJs due to soldermask c

ompression during cyclic 

operation"—solder mask is much too soft and too thin; now, if you talk 

encapsulants that is a different story.

Second, "all of the other issues pale in the face of fractured SJs due to 

soldermask compression during cyclic operation"—even if it were an issue, a 

failure is a failure is a failure—'nough said.

Werner





 





 



-----Original Message-----

From: Chris Ball <[log in to unmask]>

To: [log in to unmask]

Sent: Thu, Sep 17, 2009 1:07 pm

Subject: [TN] fractured SJs due to soldermask compression





















Hello,



Starting a new branch here.



"All of the other issues pale in the face of fractured SJs due to

soldermask compression during cyclic operation."



Is this concern specifically for BGAs, or the same for any soldermask

defined pad, even including selectively waved through-hole (PbFree)?



Thanks,

-Chris















This e-mail message is intended only for the use of the intended recipient(s).

The information contained therein may be confidential or privileged, and its 

disclosure or reproduction is strictly prohibited.

If you are not the intended recipient, please return it immediately to its 

sender at the above address and destroy it. 



---------------------------------------------------

Technet Mail List provided as a service by IPC using LISTSERV 15.0

To unsubscribe, send a message to [log in to unmask] with following text in

the BODY (NOT the subject field): SIGNOFF Technet

To temporarily20halt or (re-start) delivery of Technet send e-mail to 

Listse

[log in to unmask]: SET Technet NOMAIL or (MAIL)

To receive ONE mailing per day of all the posts: send e-mail to 

[log in to unmask]: SET Technet Digest

Search the archives of previous posts at: http://listserv.ipc.org/archives

Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for 

additional information, or contact Keach Sasamori at [log in to unmask] or 

847-615-7100 ext.2815

-----------------------------------------------------







 





---------------------------------------------------

Technet Mail List provided as a service by IPC using LISTSERV 15.0

To unsubscribe, send a message to [log in to unmask] with following text in

the BODY (NOT the subject field): SIGNOFF Technet

To temporarily halt or (re-start) delivery of Technet send e-mail to 

[log in to unmask]: SET Technet NOMAIL or (MAIL)

To receive ONE mailing per day of all the posts: send e-mail to 

[log in to unmask]: SET Technet Digest

Search the archives of previous posts at: http://listserv.ipc.org/archives

Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for 

additional information, or contact Keach Sasamori at [log in to unmask] or 

847-615-7100 ext.2815

-----------------------------------------------------







 





---------------------------------------------------

Technet Mail List provided as a service by IPC using LISTSERV 15.0

To unsubscribe, send a message to [log in to unmask] with following text in

the BODY (NOT the subject field): SIGNOFF Technet

To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)

To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest

Search the archives of previous posts at: http://listserv.ipc.org/archives

Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815

-----------------------------------------------------


ATOM RSS1 RSS2