Ioan,

I've always used the technique shown in IPC-A-620 section 15.2.1 to make easy connections to a circuit board when not using a connector.  For strain relief I might put a wire tie (ty-wrap) around the wire and through a hole or pair of holes in the circuit board.

For soldering the drain (pick-off) wire there are several methods.  One method is a heat shrinkable sleeve that contains flux and solder so the whole solder and insulation step is combined into one by using a heat shrink gun.  Another method is to lap solder or wrap the drain wire around the braid and hand solder followed by possible cleaning and heat shrink covering.  Depending on space and desired connections the drain wire can be led off in either direction, up the wire or towards the end termination.

Hope this helps.

Phil Nutting

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Ioan Tempea
Sent: Thursday, September 03, 2009 9:46 AM
To: [log in to unmask]
Subject: [TN] Soldering of coax cable on PCB

Dear Technos,



We have this coax cable that is currently connecting to the PCB via the regular connectors,

see http://www.tycoelectronics.com/catalog/bin/TE.Connect?C=1&M=BYPN&TCPN=1408150-1&RQPN=1408150-1



For various reasons we would rather eliminate the connector and solder the cable directly to the board. What is the good practice in doing that? I mean:

How the cable can be mechanically secured to the board?

How the cable must be prepared (stripped, etc.)

Any other concerns?



Thank you,



Ioan Tempea, ing.

Ingénieur Principal Fabrication / Sr. Manufacturing Engineer





30 ans déjà! - 30 years already!

950 rue Bergar, Laval, Québec, H7L 5A1

t : 450-967-7100 ext : 244

Mtl : 514-990-5762

f : 450-967-7444

[log in to unmask] <mailto:[log in to unmask]>

www.digico.cc <http://www.digico.cc/>

P N'imprimer que si nécessaire - Print only if you must




---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------


Note: All the information contained in this e-mail and its attachments is proprietary to Kaiser Systems, Inc. and it may not be reproduced without the prior written permission of sender.  If you have received this email in error, please immediately return it to sender and delete the copy you received.

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2