If it's connected to ground and has a pwr layer directly beneath then 
there will be a distributed capacitance benefit for bypassing.

At 05:11 AM 9/17/2009, Eric CHRISTISON wrote:
>Inge,
>
>If the big slab of metal in the device isn't connected to the PWB ground
>then it can make things worse, not better. If it is, then I agree with
>you that it will have a shielding effect.
>
>Regards,
>
>
>
>Terry Kozlyk wrote:
> > Hi Inge;
> >
> > Disturb away ! I find your 2 questions very good. Very good points !!!
> >
> >  TDKtalks (Terry)
> > ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
> > Terry D.Kozlyk ACS, CL, C.E.T.
> > TDKtalksTM  PodCast
> > TDKtalksTM  Blog
> > Silver Springs Toastmasters - Club #3987
> > [log in to unmask]
> > [log in to unmask]
> > home    (403) 239-7939
> > work     (403) 295-6773
> > ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
> >
> >
> > -----Original Message-----
> > From: TechNet [mailto:[log in to unmask]] On Behalf Of Hernefjord Ingemar
> > Sent: Thursday, September 17, 2009 2:33 AM
> > To: [log in to unmask]
> > Subject: Re: [TN] Ground Pour Under BGA
> >
> >  Hi,
> > CADing boards is not my job, but I became curious when I read 
> your pingpong.
> > We have a board with a number of SuperBGAs, number of balls about 660.Vias
> > in pad.  I  have two questions for you professionals. 1)what's the benefit
> > with a groundplane (that looks more like a copper net)under chip, when the
> > whole BGA has a thick metal plate all over the BGA. That metal sheet is
> > mainly for cooling and stabilizing the body mechanically, but isn't this
> > cover  also a effective ground plane and a electrostatic shield? 
> 2)will such
> > an extra groundplane under chip make 3D X-raying even harder to read, e.g.
> > bond wires, which are already hard to inspect due to the massive top metal
> > plate.
> > Sorry for disturbing you with such trivia.
> > /Inge
> >
> > -----Original Message-----
> > From: TechNet [mailto:[log in to unmask]] On Behalf Of Dwight Mattix
> > Sent: onsdag 16 september 2009 17:26
> > To: [log in to unmask]
> > Subject: Re: [TN] Ground Pour Under BGA
> >
> > yes. If BGA pitch is large enough then it makes nice little pwr/gnd island
> > with some distributed capacitance directly under the device (available with
> > very low inductance).
> > When picking and choosing which of several device voltages to 
> locate thusly,
> > for greatest benefit use it for the heavy fast currents (e.g.
> > core voltages).
> >
> > At 07:16 AM 9/16/2009, Kenneth Wood wrote:
> >
> >> Keep in mind that on HDI designs you are not JUST adding a few micro
> >> vias and pouring GND on the top layer...you are using via-in-pad on all
> >> devices so to try and minimize top side pour cuts. Also, you are
> >> routing as many nets on internal layers as possible.
> >> The top layer GND is not usually the only GND plane too, there is
> >> usually an internal plane to back up the top layer.
> >> This does reduce EMI significantly, shorter runs and external shielding
> >> works.
> >> Ken
> >> Saturn PCB Design, Inc.
> >> www.saturnpcb.com
> >>
> >>
> >>
> >> -----Original Message-----
> >> From: TechNet [mailto:[log in to unmask]] On Behalf Of Robert Kondner
> >> Sent: Wednesday, September 16, 2009 10:07 AM
> >> To: [log in to unmask]
> >> Subject: Re: [TN] Ground Pour Under BGA
> >>
> >> Ken,
> >>
> >>   With all the BGA pads and possible vias I don't see how a top side
> >> can have a better mesh of copper paths than an internal layer. I would
> >> think a poor copper mesh plane would be a generator of large GND return
> >> loops. Aka antennas.
> >>
> >>  As for a GND plane being a few mils closer to the BGA and this
> >> reducing EMI, that sounds like hog wash. Consider that conductor
> >> lengths from a ball to chip is probably about 1/2 inch at times. How is
> >> adding 10 mils going to affect anything?
> >>
> >>  I am open to Hog Wash ideas but they need to be well defined.
> >>
> >> Thanks,
> >> Bob Kondner
> >>
> >>
> >> -----Original Message-----
> >> From: TechNet [mailto:[log in to unmask]] On Behalf Of Kenneth Wood
> >> Sent: Wednesday, September 16, 2009 9:54 AM
> >> To: [log in to unmask]
> >> Subject: Re: [TN] Ground Pour Under BGA
> >>
> >> It is an technique used in HDI designs that utilize micro vias.
> >> Top layer is GND and layer 2 can be a power layer. It also helps with EMI.
> >> Ken
> >> Saturn PCB Design, Inc.
> >> www.saturnpcb.com
> >>
> >>
> >> -----Original Message-----
> >> From: TechNet [mailto:[log in to unmask]] On Behalf Of Robert Kondner
> >> Sent: Wednesday, September 16, 2009 8:42 AM
> >> To: [log in to unmask]
> >> Subject: Re: [TN] Ground Pour Under BGA
> >>
> >> Hi,
> >>
> >>   What would be the goal of placing atop side GND plane under the BGA?
> >>
> >>   Low Z Gnd return? Electrostatic shield?
> >>
> >>   Having a plane under the BGA vs another layer is not going to make a
> >> difference in plane Z.
> >>
> >>  Sounds like a good chance of creating shorts if the solder mask chips
> >> or is damaged during rework.
> >>
> >> Bob Kondner
> >>
> >> -----Original Message-----
> >> From: TechNet [mailto:[log in to unmask]] On Behalf Of Guy Ramsey
> >> Sent: Wednesday, September 16, 2009 7:43 AM
> >> To: [log in to unmask]
> >> Subject: Re: [TN] Ground Pour Under BGA
> >>
> >> IPC 7095, BGA Technology by Lau.
> >>
> >> -----Original Message-----
> >> From: TechNet [mailto:[log in to unmask]] On Behalf Of Toby Carrier
> >> Sent: Tuesday, September 15, 2009 8:45 PM
> >> To: [log in to unmask]
> >> Subject: [TN] Ground Pour Under BGA
> >>
> >> Hello all,
> >>
> >> Is it a good idea to create a top layer ground flood under a BGA
> >> package? I am guessing that the fanout will not allow much area for the
> >> ground pour, am I correct in thinking so? Does anyone have any good
> >> reference info on this topic?
> >>
> >> Also, if you don't have a ground pour under the BGA, how will that
> >> affect the impedance control of the traces going to the BGA ball?
> >>
> >> Thanks for the help,
> >>
> >> Toby
> >>
> >> ---------------------------------------------------
> >> Technet Mail List provided as a service by IPC using LISTSERV 15.0 To
> >> unsubscribe, send a message to [log in to unmask] with following text in
> >> the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt
> >> or (re-start) delivery of Technet send e-mail to
> >> [log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing
> >> per day of all the posts: send e-mail to
> >> [log in to unmask]: SET Technet Digest
> >> Search the archives of previous posts at:
> >> http://listserv.ipc.org/archives Please visit IPC web site
> >> http://www.ipc.org/contentpage.asp?Pageid=4.3.16
> >> for additional information, or contact Keach Sasamori at [log in to unmask]
> >> or 847-615-7100 ext.2815
> >> -----------------------------------------------------
> >>
> >> ---------------------------------------------------
> >> Technet Mail List provided as a service by IPC using LISTSERV 15.0 To
> >> unsubscribe, send a message to [log in to unmask] with following text in
> >> the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt
> >> or (re-start) delivery of Technet send e-mail to
> >> [log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing
> >> per day of all the posts: send e-mail to
> >> [log in to unmask]: SET Technet Digest
> >> Search the archives of previous posts at:
> >> http://listserv.ipc.org/archives Please visit IPC web site
> >> http://www.ipc.org/contentpage.asp?Pageid=4.3.16
> >> for additional information, or contact Keach Sasamori at [log in to unmask]
> >> or 847-615-7100 ext.2815
> >> -----------------------------------------------------
> >>
> >> ---------------------------------------------------
> >> Technet Mail List provided as a service by IPC using LISTSERV 15.0 To
> >> unsubscribe, send a message to [log in to unmask] with following text in
> >> the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt
> >> or (re-start) delivery of Technet send e-mail to
> >> [log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing
> >> per day of all the posts: send e-mail to
> >> [log in to unmask]: SET Technet Digest
> >> Search the archives of previous posts at:
> >> http://listserv.ipc.org/archives Please visit IPC web site
> >> http://www.ipc.org/contentpage.asp?Pageid=4.3.16
> >> for additional information, or contact Keach Sasamori at [log in to unmask]
> >> or 847-615-7100 ext.2815
> >> -----------------------------------------------------
> >>
> >> ---------------------------------------------------
> >> Technet Mail List provided as a service by IPC using LISTSERV 15.0 To
> >> unsubscribe, send a message to [log in to unmask] with following text in
> >> the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt
> >> or (re-start) delivery of Technet send e-mail to
> >> [log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing
> >> per day of all the posts: send e-mail to
> >> [log in to unmask]: SET Technet Digest
> >> Search the archives of previous posts at:
> >> http://listserv.ipc.org/archives Please visit IPC web site
> >> http://www.ipc.org/contentpage.asp?Pageid=4.3.16
> >> for additional information, or contact Keach Sasamori at [log in to unmask]
> >> or 847-615-7100 ext.2815
> >> -----------------------------------------------------
> >>
> >> ---------------------------------------------------
> >> Technet Mail List provided as a service by IPC using LISTSERV 15.0 To
> >> unsubscribe, send a message to [log in to unmask] with following text in
> >> the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt
> >> or (re-start) delivery of Technet send e-mail to
> >> [log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing
> >> per day of all the posts: send e-mail to
> >> [log in to unmask]: SET Technet Digest
> >> Search the archives of previous posts at:
> >> http://listserv.ipc.org/archives Please visit IPC web site
> >> http://www.ipc.org/contentpage.asp?Pageid=4.3.16
> >> for additional information, or contact Keach Sasamori at [log in to unmask]
> >> or 847-615-7100 ext.2815
> >> -----------------------------------------------------
> >>
> >> ---------------------------------------------------
> >> Technet Mail List provided as a service by IPC using LISTSERV 15.0 To
> >> unsubscribe, send a message to [log in to unmask] with following text in
> >> the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt
> >> or (re-start) delivery of Technet send e-mail to
> >> [log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing
> >> per day of all the posts: send e-mail to
> >> [log in to unmask]: SET Technet Digest
> >> Search the archives of previous posts at:
> >> http://listserv.ipc.org/archives Please visit IPC web site
> >> http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
> >> information, or contact Keach Sasamori at [log in to unmask] or
> >> 847-615-7100 ext.2815
> >> -----------------------------------------------------
> >>
> >
> > ---------------------------------------------------
> > Technet Mail List provided as a service by IPC using LISTSERV 15.0 To
> > unsubscribe, send a message to [log in to unmask] with following text in the
> > BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
> > (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet
> > NOMAIL or (MAIL) To receive ONE mailing per day of all the posts: send
> > e-mail to [log in to unmask]: SET Technet Digest Search the archives of
> > previous posts at: http://listserv.ipc.org/archives Please visit IPC web
> > site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
> > information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
> > ext.2815
> > -----------------------------------------------------
> >
> > ---------------------------------------------------
> > Technet Mail List provided as a service by IPC using LISTSERV 15.0
> > To unsubscribe, send a message to [log in to unmask] with following text in
> > the BODY (NOT the subject field): SIGNOFF Technet
> > To temporarily halt or (re-start) delivery of Technet send e-mail to
> > [log in to unmask]: SET Technet NOMAIL or (MAIL)
> > To receive ONE mailing per day of all the posts: send e-mail to
> > [log in to unmask]: SET Technet Digest
> > Search the archives of previous posts at: http://listserv.ipc.org/archives
> > Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
> > for additional information, or contact Keach Sasamori at [log in to unmask] or
> > 847-615-7100 ext.2815
> > -----------------------------------------------------
> >
> > ---------------------------------------------------
> > Technet Mail List provided as a service by IPC using LISTSERV 15.0
> > To unsubscribe, send a message to [log in to unmask] with following text in
> > the BODY (NOT the subject field): SIGNOFF Technet
> > To temporarily halt or (re-start) delivery of Technet send e-mail 
> to [log in to unmask]: SET Technet NOMAIL or (MAIL)
> > To receive ONE mailing per day of all the posts: send e-mail to 
> [log in to unmask]: SET Technet Digest
> > Search the archives of previous posts at: http://listserv.ipc.org/archives
> > Please visit IPC web site 
> http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional 
> information, or contact Keach Sasamori at [log in to unmask] or 
> 847-615-7100 ext.2815
> > -----------------------------------------------------
> >
> >
>
>--
>Eric Christison Msc
>Mechanical Engineer
>Consumer & Micro group
>Imaging Division
>
>STMicroelectronics (R&D) Ltd
>33 Pinkhill
>Edinburgh EH12 7BF
>United Kingdom
>
>Tel:    +44 (0)131 336 6165
>Fax:    + 44 (0)131 336 6001
>
>---------------------------------------------------
>Technet Mail List provided as a service by IPC using LISTSERV 15.0
>To unsubscribe, send a message to [log in to unmask] with following text in
>the BODY (NOT the subject field): SIGNOFF Technet
>To temporarily halt or (re-start) delivery of Technet send e-mail to 
>[log in to unmask]: SET Technet NOMAIL or (MAIL)
>To receive ONE mailing per day of all the posts: send e-mail to 
>[log in to unmask]: SET Technet Digest
>Search the archives of previous posts at: http://listserv.ipc.org/archives
>Please visit IPC web site 
>http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional 
>information, or contact Keach Sasamori at [log in to unmask] or 
>847-615-7100 ext.2815
>-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2