TECHNET Archives

August 2009

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Joyce Koo <[log in to unmask]>
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, Joyce Koo <[log in to unmask]>
Date:
Mon, 3 Aug 2009 13:58:18 -0400
Content-Type:
text/plain
Parts/Attachments:
text/plain (95 lines)
Contact eastern in japan.  If they tell you they can't do it, slap your designer and get him out of the computer dream land. 
--------------------------
Sent using BlackBerry


----- Original Message -----
From: TechNet <[log in to unmask]>
To: [log in to unmask] <[log in to unmask]>
Sent: Mon Aug 03 10:58:12 2009
Subject: Re: [TN] Looking for a fabricator for a .65mm bga brd

Did you say "production environment?"

ruh-rohhh
/scooby doo voice off

Assuming solid 14x14 array with no open rows and PTH with single 
track 3/3 l/s escape routing.

.65mm pitch = 25.6 mil spacing
3/3/3 space/line/space = takeaway 9 mils from 25.6

Leaves room for drill pad = 16.9 mils

Drill + 10 is general rule for production so that means a 6-7 mil 
through drill?

That's without considering power and isolation requirements and 
additional layers to manage other hookup issues.
Minimum 7 rows/7 layers minimum just to escape from the device 
center. More likely 8-9 routing layers.


can you say "uVias?"   .:-)


At 07:22 AM 8/3/2009, Barbara Burcham wrote:
>I am working on a layout that has a 0.65mm 14x14 matrix bga on an 0.062
>thick board. I have to be able to place through hole vias between the pads.
>Would love to use 3 and 3 spacing.
>Who out there can advise me about this?
>Yes, the board HAS to be 0.062 thk...has a card edge connector...but can be
>on the low side of that.
>Yes, we really want to use through hole vias.
>We can use 1/2 oz copper on all 8 layers.
>The board is small and can easily be run on a smaller production panel to
>improve tolerances.
>So, how small a capture pad and hole can be done in a production
>environment, reliably?
>Need to get this nailed down today.
>
>Barbara Burcham, C.I.D.
>pcb Trace Design
>281-341-7539 Wk/Hm
>713-249-7718 Cell
>[log in to unmask]
>
>---------------------------------------------------
>Technet Mail List provided as a service by IPC using LISTSERV 15.0
>To unsubscribe, send a message to [log in to unmask] with following text in
>the BODY (NOT the subject field): SIGNOFF Technet
>To temporarily halt or (re-start) delivery of Technet send e-mail to 
>[log in to unmask]: SET Technet NOMAIL or (MAIL)
>To receive ONE mailing per day of all the posts: send e-mail to 
>[log in to unmask]: SET Technet Digest
>Search the archives of previous posts at: http://listserv.ipc.org/archives
>Please visit IPC web site 
>http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional 
>information, or contact Keach Sasamori at [log in to unmask] or 
>847-615-7100 ext.2815
>-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------------------------
This transmission (including any attachments) may contain confidential information, privileged material (including material protected by the solicitor-client or other applicable privileges), or constitute non-public information. Any use of this information by anyone other than the intended recipient is prohibited. If you have received this transmission in error, please immediately reply to the sender and delete this information from your system. Use, dissemination, distribution, or reproduction of this transmission by unintended recipients is not authorized and may be unlawful.

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2