Did you say "production environment?"

ruh-rohhh
/scooby doo voice off

Assuming solid 14x14 array with no open rows and PTH with single 
track 3/3 l/s escape routing.

.65mm pitch = 25.6 mil spacing
3/3/3 space/line/space = takeaway 9 mils from 25.6

Leaves room for drill pad = 16.9 mils

Drill + 10 is general rule for production so that means a 6-7 mil 
through drill?

That's without considering power and isolation requirements and 
additional layers to manage other hookup issues.
Minimum 7 rows/7 layers minimum just to escape from the device 
center. More likely 8-9 routing layers.


can you say "uVias?"   .:-)


At 07:22 AM 8/3/2009, Barbara Burcham wrote:
>I am working on a layout that has a 0.65mm 14x14 matrix bga on an 0.062
>thick board. I have to be able to place through hole vias between the pads.
>Would love to use 3 and 3 spacing.
>Who out there can advise me about this?
>Yes, the board HAS to be 0.062 thk...has a card edge connector...but can be
>on the low side of that.
>Yes, we really want to use through hole vias.
>We can use 1/2 oz copper on all 8 layers.
>The board is small and can easily be run on a smaller production panel to
>improve tolerances.
>So, how small a capture pad and hole can be done in a production
>environment, reliably?
>Need to get this nailed down today.
>
>Barbara Burcham, C.I.D.
>pcb Trace Design
>281-341-7539 Wk/Hm
>713-249-7718 Cell
>[log in to unmask]
>
>---------------------------------------------------
>Technet Mail List provided as a service by IPC using LISTSERV 15.0
>To unsubscribe, send a message to [log in to unmask] with following text in
>the BODY (NOT the subject field): SIGNOFF Technet
>To temporarily halt or (re-start) delivery of Technet send e-mail to 
>[log in to unmask]: SET Technet NOMAIL or (MAIL)
>To receive ONE mailing per day of all the posts: send e-mail to 
>[log in to unmask]: SET Technet Digest
>Search the archives of previous posts at: http://listserv.ipc.org/archives
>Please visit IPC web site 
>http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional 
>information, or contact Keach Sasamori at [log in to unmask] or 
>847-615-7100 ext.2815
>-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2