Werner Engelmaier /* <[log in to unmask]>
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, [log in to unmask]
Date:
Thu, 13 Aug 2009 23:17:32 -0400
Content-Type:
text/plain
Parts/Attachments:
text/plain (75 lines)
 Hi Colin,


 First, CTE's are not rates—they are time-independent.
Second, CTE's are the same on heating and cooling, with the exception of polymers which can show a hysteresis behavior.
Third, indeed, the cooling rates can too fast—remember, that you have quite a different structure after soldering than before.
Werner


 

-----Original Message-----
From: colin mcvean <[log in to unmask]>
To: [log in to unmask]
Sent: Thu, Aug 13, 2009 11:04 pm
Subject: [TN] Reflow profile










Folks,
 
From my previous question regarding pattern crack we are seeing on a wire-bonded 
flex-rigid PCB, I have now found more evidence that the presented FPCB is ok, 
but after reflow for SMT assembly, this is where the cracking is first found 
(rather than after wire-bond process). The reflow profile being used peaks at 
245oC, but rapidly cools from peak to 135oC in about 30s. This seems to me to be 
too rapid a cool rate, and with the pad metallics being 0.2uM gold over 10uM 
Nickel over 30uM copper pad. Are CTE rates on cooling the same as CTE rates for 
heating? I think I may have CTE mismatch on the coatings, which when cooled too 
rapidly, are causing the crack. Any metallurgists out there willing to comment?
 
Thanks
 
Colin


      

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): 
SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to 
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to 
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for 
additional information, or contact Keach Sasamori at [log in to unmask] or 
847-615-7100 ext.2815
-----------------------------------------------------



 


---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2