Sounds like you have voiding in the vias - volatile entrapment and out-gassing during TE.
Jeffrey Bush
Sr. Principle Product Assurance Engineer
Space Systems and Electronics - Performance Excellence
BAE SYSTEMS
P.O. Box 868, MER24-116A
Nashua, NH 03061-0868
Facility: 144 DW Highway
Merrimack, NH 03054
Office +1 603.885.8137
Mobile +1 603.318.8056
Fax +1 603.885.5258
-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Chris Mahanna
Sent: Wednesday, August 26, 2009 9:34 PM
To: [log in to unmask]
Subject: [TN] Via-in-pad blowing bubbles
Hello netters-
Have we a term for vias-in-pad blowing solder ball bubbles to the point of bridging?
Regardless, is there a unique cure for the problem?
I wonder because- how does one get just enough pressure to blow the large bubble, but not blow-out? Bad luck?
Or is it not that unusual, and just usually gets screened before it gets to me?
Chris
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|