Craig,
You often see conductors extremly close to the edge in order to use as much 
as possible of the area. Understandable but risky. The edges are sensitive 
to touching leading rails, mechanicl damage by handling and cracks in the 
coating etc. Therefore, our guys have decided own rules, hence we have a 
minimum of 1 millimeter as a safety distance for signals and data traces and 
5 millimeters for power lines.
Inge

----- Original Message ----- 
From: "Craig Sullivan" <[log in to unmask]>
To: <[log in to unmask]>
Sent: Wednesday, August 19, 2009 9:34 PM
Subject: [TN] Minimum Conductor to PCB edge distance


I can't seem to find this information in any IPC document, unless I am
obviously overlooking it.

We have a PCB customer designed with a trace close to the board edge
(0.013"). However, when the board is scored for depaneling, the score width
reduces the distance to around 0.005" - 0.007".

Can anyone recommend a reference or design guideline that specifies
something like this? Something that may specify how close features can be
placed to the board edge?

We have our own guidelines for DFA, and generally speaking, we've never run
into anything this tight where it's become a cause for concern. But there's
also a first time I suppose.

Thanks in advance for the input.
Craig

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to 
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to 
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 
for additional information, or contact Keach Sasamori at [log in to unmask] or 
847-615-7100 ext.2815
----------------------------------------------------- 

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2