Yes, but it gives me an excuse. Doug only has Mt. Dew to blame. That was
the best job I could ever have. I would dream up these things to invent
and they would give me the money. As the one VP would say "I would
rather just give him the money than try to figure out what he just said
or when the inevitable "Dewey"ism was going to be interjected".
Dewey

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of David D. Hillman
Sent: Wednesday, July 08, 2009 2:45 PM
To: [log in to unmask]
Subject: Re: [TN] NTC - IPC High Voltage PCB Marking and Spacing

Hi Dewey - Ya know, your story would explain the source of Dewey-isms
and 
quite a few other things.........................


Dave Hillman
Rockwell Collins
[log in to unmask]



"Whittaker, Dewey (EHCOE)" <[log in to unmask]> 
Sent by: TechNet <[log in to unmask]>
07/08/2009 04:31 PM
Please respond to
TechNet E-Mail Forum <[log in to unmask]>; Please respond to
"Whittaker, Dewey (EHCOE)" <[log in to unmask]>


To
[log in to unmask]
cc

Subject
Re: [TN] IPC High Voltage PCB Marking and Spacing






I'll tell you this story and everyone will go aah-huh!
I designed (patents pending 38 years ago) and developed a 200,000 volts
DC paint spray system. I had the same very large steel net cage area on
an isolated second floor with all the safety devices and static drains.
After completion of the test the ritual was to slowly drain the charge
and remove the hose from the test stanchions. Something went wrong (I
can't believe it was sabotage), the hose was OK but the stanchions did
not drain and became a giant charged capacitor. I came to (gives a new
meaning to field of dreams) awhile later with a strong aversion to the
smell of ozone.
Dewey 

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Inge
Sent: Wednesday, July 08, 2009 1:49 PM
To: [log in to unmask]
Subject: Re: [TN] IPC High Voltage PCB Marking and Spacing

I would like a more dramatic label : Warning! You are in Danger! If I
saw 
that I would look around, take a few steps back and go to a safer place.

Reminds me when I made some tests in a steel net cage with a 50,000 Volt

transformer. Only label was a little sign on the door :  Lock the door
after 
you!

Another peculiar memory. A engineer had built plexi box for testing
TWTs. He 
had built in security switches so that the high voltage be broken if
someone 
opened the door. One day, we found him on the floor, plexi box door open
and 
security switches taped over. He survived.

But high voltage can be fun too. When young, I had very thick rubber
shoes. 
Put finger on 100 Meg resistor connected to red terminal, and charged
myself 
to 20 kV (don't do that with a supply that can generate more than 10 mA
!) 
and walked out in the corridor. Saw some of the others and used index 
finger, pointed close to the guy's nose and said 'you got something
there, 
have you cut yourself? ' . Well, in one such case of practical joke, I
had 
to run. My victim had a short fuse.

And the revenge was not far off. One day, I sat down as usual at my lab 
bench, rolled the chair closer to the bench and ...SPRZZZT!... 20 kV 
directly into my leg. They had used a high voltage cable from the other 
room, connected it to the bench steel frame (standing on nylon feet) and

..you understand what of course.

From fun to reality. It's necessary to respect the laws and use safety 
arrangements. Too many people die every year from current (not voltage).
And 
many are electricians and other technical guys. To be in the game is not
the 
same as being safe. Far from. We who use electrical equipments daily are

presumptive victims more often than we think. I will end this little
extra 
with a advice from my days working with dangerous boxes : one hand on 
screwdriver, the other in the pocket....means: keep and eye on your left

hand when your right hand is in a working equipment. Has saved many
lives.

Inge

----- Original Message ----- 
From: "Phil Nutting" <[log in to unmask]>
To: <[log in to unmask]>
Sent: Wednesday, July 08, 2009 9:49 PM
Subject: Re: [TN] IPC High Voltage PCB Marking and Spacing


Toby,

We use the creepage and clearance requirements as outlined in EN60601, 
EN601, IEC950, etc.

For marking I use the European triangle with the lightning bolt/arrow.

If wording is used I use the requirements of ANSI Z535.6 to determine
the 
level of hazard presented by the high voltage;

Is death or serious injury a credible possibility?   If No, then use
CAUTION
If hazardous situation occurs, how likely is accident?  If Possible,
then 
use WARNING
If accident occurs, how likely is death or serious injury?  If Possible,

then use WARNING
If accident occurs, how likely is death or serious injury?  If Almost 
Certain, then use DANGER

The use of Danger versus Warning is a bit subjective.  Take into 
consideration the voltage and current levels present in the hazard.

I hope this helps,

Phil Nutting
Design for Manufacturing Engineer
Kaiser Systems, Inc.
126 Sohier Road
Beverly, MA 01915
voice: 978-922-9300 x1310
fax: 978-922-8374
e-mail: [log in to unmask]
www.kaisersystems.com


-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Toby Carrier
Sent: Wednesday, July 08, 2009 3:20 PM
To: [log in to unmask]
Subject: [TN] IPC High Voltage PCB Marking and Spacing

Hi All,

Does anyone know of an IPC standard that states a requirement of high
voltage spacing and marking? I know that UL requires spacing based on
the
voltage, but not for sure about IPC. Thanks for the help.

Toby
Engineering Technician

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to 
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to 
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 
for additional information, or contact Keach Sasamori at [log in to unmask]
or 
847-615-7100 ext.2815
-----------------------------------------------------


Note: All the information contained in this e-mail and its attachments
is 
proprietary to Kaiser Systems, Inc. and it may not be reproduced without
the 
prior written permission of sender.  If you have received this email in 
error, please immediately return it to sender and delete the copy you 
received.

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to 
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to 
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 
for additional information, or contact Keach Sasamori at [log in to unmask]
or 
847-615-7100 ext.2815
----------------------------------------------------- 

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to 
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to 
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 
for additional information, or contact Keach Sasamori at [log in to unmask]
or 
847-615-7100 ext.2815
-----------------------------------------------------


---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2