Greg and fellow Techies
I am in the process of submitting revisions to solder paste tests
called up in TM-650 and need your help.
In 2.4.43 Solder Ball - 2.4.45 Wetting and 2.4.46 Spread Tests, we
need to allow for lead-free alloys. In each of these there is a quoted
time:
"The reflow shall occur within 20 seconds after the specimen is placed
in contact with the hot plate."
The recommendation is to include the following:
"For lead-free solder pastes, the reflow time shall occur within 30
seconds after the specimen is placed in contact with the hot plate."
Does anyone out there in Techieland have any objections to this
proposed addition to each of these test methods?
Thanks in advance
Regards
Graham Naisbitt
Managing Director
E: [log in to unmask]
P: +44 12 5252 1500
F: +44 12 5252 1112
W: www.gen3systems.com
GEN3 SYSTEMS LIMITED
Incorporating Process Support Products
Unit B2, Armstrong Mall
Southwood Business Park
FARNBOROUGH
Hampshire GU14 0NR - UK
Engineering Reliability in Electronics
Registered Number: 4639449 (England & Wales). Registered Office as
above.
DISCLAIMER : This message is intended only for the use of the
individual or entity to which it is addressed and may contain
information which is privileged, confidential, proprietary, or exempt
from disclosure under applicable law. If you are not the intended
recipient or the person responsible for delivering the message to the
intended recipient, you are strictly prohibited from disclosing,
distributing, copying, or in any way using this message. If you have
received this communication in error, please notify the sender and
destroy and delete any copies you may have received. Any views or
opinions presented in this email are solely those of the author and
might not represent those of Gen3 Systems Limited. Although Gen3
Systems Limited has taken reasonable precautions to ensure no viruses
present in this email, Gen3 Systems Limited can not accept the
responsibility for any loss or damage arising from the use of this
email or attachments.
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|