Now that I come to think of it, in the 1940s I drank IPA, India Pale 
Ale. As I no longer drink beer, I had to look it up to see if it still 
exists. http://en.wikipedia.org/wiki/India_Pale_Ale - it does.

Brian

Whittaker, Dewey (EHCOE) wrote:
> Several times, full of IPA (Intoxicating Pale Ales) I have found myself
> sitting in a Jacuzzi.
> Dewey
> 
> -----Original Message-----
> From: TechNet [mailto:[log in to unmask]] On Behalf Of Bev Christian
> Sent: Tuesday, June 30, 2009 8:59 AM
> To: [log in to unmask]
> Subject: Re: [TN] NTC [TN] IPA or Methanol in Ultrasonic Cleaner
> 
> Well it is sort of like Friday for me, since tomorrow is Canada Day. 
> 
> Lee,
> I would never sit in a Jacuzzi full of IPA. 
> Bev
> 
> ----- Original Message -----
> From: TechNet <[log in to unmask]>
> To: [log in to unmask] <[log in to unmask]>
> Sent: Tue Jun 30 11:40:22 2009
> Subject: Re: [TN] IPA or Methanol in Ultrasonic Cleaner
> 
> Since this is a global distribution, Brian's testimony reminds me of a
> visit my former manager made overseas. At the board shop, my manager
> witnessed a vapor degreaser being used, filled with IPA. While it worked
> fine in "cleaning" the hardware, with over 25 gallons of IPA near
> boiling, my manager left the premises rather quickly.
> 
> BTW - the flash point of IPA is 12C. The flash point of methanol is 11C.
> With such a low flash point, I would be extremely careful about using
> either in an ultrasonic cleaner. With a Jet Clean (aka Jacuzzi), yes and
> I've done that. But with ultrasonics, I would be scared of putting too
> much energy into the tank, let alone the fumes that it would create.
> 
> Along similar lines, at the Indy 500, there was a fire in the pits
> several years ago. Remember, the CART cars use methanol not gasoline as
> a fuel, which burns invisibly. They tried using water, but that made the
> situation worse until they used a fire extinguisher (type unknown but I
> think it was a halogen).
> 
> Lee Whiteman, PMP
> Senior Member Engineering Staff
> L-3 Communications East
> Telephone: (856) 338-3508
> FAX: (856) 338-2906
> E-Mail: [log in to unmask]
>  
> -----Original Message-----
> From: TechNet [mailto:[log in to unmask]] On Behalf Of Brian Ellis
> Sent: Tuesday, June 30, 2009 11:12 AM
> To: [log in to unmask]
> Subject: Re: [TN] IPA o r Methanol in Ultrasonic Cleaner
> 
> There has been at least one fire in a contamination tester that I know 
> of for certain. The company in question thereafter decreed that all 
> flammable solutions and products should be used only in metallic 
> enclosures because the PVC melted, allowing the burning solution to 
> spread along the floor, causing considerable collateral damage to the 
> workshop (I think in millions). I have heard of a possible couple of 
> other minor cases but nothing that I can quote chapter and verse on.
> 
> Remember that the vapours from testers are the IPA/water azeotrope and 
> not pure IPA. Even the small amount of water, not affecting the flash 
> point, does reduce the ease with which it burns.
> 
> As an ex-manufacturer of contamination testers, we took care in the 
> design to minimise the risk, although it can never be eliminated. I 
> emphasise that the one that caused all the damage was not of our 
> manufacture! :-o
> 
> By the same token, the bottle of Laphroaig in the CEO's cocktail cabinet
> 
> has an EtOH/water azeotrope over the liquid level, but it has a better 
> aroma and flavour than the contamination tester solution.
> 
> Brian
> 
> Richard Kraszewski wrote:
>> We have done US cleaning using higher molecular weight alcohols and
>> found them to be rather effective, especially in cleaning beneath low
>> stand off components. 
>>
>> Using lower weight and lower boiling alcohols like MeOH, EtOH or IPA
>> just doesn't work well, so why even take the risk,  albeit the risk is
>> rather low.  Remember that ROSE tester solution (~75% IPA) can get
>> rather warm after awhile and I haven't heard about many (any?) fires
>> related to that testing operation. 
>>
>>
>> Rich Kraszewski
>>
>>
>> -----Original Message-----
>> From: TechNet [mailto:[log in to unmask]] On Behalf Of John Anselmo
>> Sent: Monday, June 29, 2009 10:27 AM
>> To: [log in to unmask]
>> Subject: [TN] IPA o r Methanol in Ultrasonic Cleaner
>>
>> Technet,
>>
>> We are being asked by one of our customers to clean some parts
> (screws,
>> washers, standoffs, feedthrus) in an ultrasonic cleaner with either
>> Methanol or IPA (spectroscopic grade).
>> The time in the ultrasonics could be up to 1 hour.
>> Does anyone else have experience and recommendations for doing this?
>> My main concern is safety.  What type of room or enclosure do we need
>> for this?
>>
>> Thanks,
>> John Anselmo
>>
>> ---------------------------------------------------
>> Technet Mail List provided as a service by IPC using LISTSERV 15.0 To
>> unsubscribe, send a message to [log in to unmask] with following text in
>> the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt
> or
>> (re-start) delivery of Technet send e-mail to [log in to unmask]: SET
>> Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the
>> posts: send e-mail to [log in to unmask]: SET Technet Digest Search the
>> archives of previous posts at: http://listserv.ipc.org/archives Please
>> visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
> for
>> additional information, or contact Keach Sasamori at [log in to unmask] or
>> 847-615-7100 ext.2815
>> -----------------------------------------------------
>>
>> ---------------------------------------------------
>> Technet Mail List provided as a service by IPC using LISTSERV 15.0
>> To unsubscribe, send a message to [log in to unmask] with following text
> in
>> the BODY (NOT the subject field): SIGNOFF Technet
>> To temporarily halt or (re-start) delivery of Technet send e-mail to
> [log in to unmask]: SET Technet NOMAIL or (MAIL)
>> To receive ONE mailing per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
>> Search the archives of previous posts at:
> http://listserv.ipc.org/archives
>> Please visit IPC web site
> http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
> information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
> ext.2815
>> -----------------------------------------------------
>>
> 
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 15.0
> To unsubscribe, send a message to [log in to unmask] with following text
> in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to
> [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at:
> http://listserv.ipc.org/archives
> Please visit IPC web site
> http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
> information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
> ext.2815
> -----------------------------------------------------
> 
> ---------------------------------------------------------------------
> This transmission (including any attachments) may contain confidential
> information, privileged material (including material protected by the
> solicitor-client or other applicable privileges), or constitute
> non-public information. Any use of this information by anyone other than
> the intended recipient is prohibited. If you have received this
> transmission in error, please immediately reply to the sender and delete
> this information from your system. Use, dissemination, distribution, or
> reproduction of this transmission by unintended recipients is not
> authorized and may be unlawful.
> 
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 15.0
> To unsubscribe, send a message to [log in to unmask] with following text
> in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to
> [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at:
> http://listserv.ipc.org/archives
> Please visit IPC web site
> http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
> information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
> ext.2815
> -----------------------------------------------------
> 
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 15.0
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/archives
> Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
> -----------------------------------------------------
> 

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2