TECHNET Archives

July 2009

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Steven Creswick <[log in to unmask]>
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, Steven Creswick <[log in to unmask]>
Date:
Wed, 15 Jul 2009 13:28:43 -0400
Content-Type:
text/plain
Parts/Attachments:
text/plain (105 lines)
John,

We did do not experience electro-migration problems in a hybrid or
multi-chip module so long as long-term hermeticity was maintained - to keep
the moisture out.

From my perspective, PEMs - plastic encapsulated modules do not possess
long-term hermeticity characteristics [am sure to ignite a firestorm with
that], but they certainly do well in the short-term, and under reasonable
environmental challenges. They delay the ingress of moisture - do they
delay it long enough for your application is the question. Optically clear
molding compounds tend to be worse because - 1) there are no expansion
modifiers present [dah!, it's clear], 2) they just don't have the ruggedness
of the filled versions ...

Therefore, whatever you do to delay the ingress will be to your benefit.
Paralyene, some of the new hydrophobic plasma coatings, careful selection
and processing [storage, handling, molding and post-cure] of the mold
compounds, plating on the lead-frame or PWB.

Depends on your requirements.... just a matter of time & voltage, it would
seem.


You did not really say whether your application was over-molded, exposed
PWB, etc...

Steve



-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of John Burke
Sent: Wednesday, July 15, 2009 1:09 PM
To: [log in to unmask]
Subject: [TN] Silver epoxy

 

Many years back (too many) I was working on silver epoxy connected hybrids
for high reliability applications.

 

I seem to recall that silver migration is a definite issue. Does anyone have
any rules for mitigating this risk such as design clearances between pads
etc?

 

Best regards,

 

 

John Burke

Director of Operations

 



http://www.optichron.com

4221 Technology Drive

Fremont, CA 94538

 

Cell (408) 515 4992

Desk (510) 249 5233

Main (510) 249 5200

 


---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2