I've been around long enough to remember our 
Baron Blakeslee vapor degreasers, filled
with the old ozone depleting solvents.

Some of these units were equipped with
ultrasonic transducers in the cool sump, and
sometimes those transducers would fail and 
burn right through the sheet steel. Imagine
if that tank had been filled with a flammable 
solvent.

I'm not even sure that IPA will cavitate
properly in an ultrasonic tank, but I'm not
about to try it and find out.

-Joe

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Mike Fenner
Sent: Tuesday, June 30, 2009 12:14 PM
To: [log in to unmask]
Subject: Re: [TN] IPA o r Methanol in Ultrasonic Cleaner

In the days before Health and safety rules, I developed with a colleague
a simple demo of the dangers of alcohol, 

Take an empty 5 litre (1 gal) poly jug. 
Introduce a couple of drops or 3 of IPA Replace cape and shake.
Remove cap and demonstrate now empty container Align container carefully
so base faces aisle between audience seats and open end is facing back
of room. 
Stand to one side
Hold flame to base of jug.
Zero point something seconds later:
Ask the people at the back of the hall to return jug.
[Alternatively go outside and do it vertically.] Conclude by saying We
have demonstrated that an empty container contains enough energy to
propel itself 50 feet or so.
A full one contains enough energy to propel an auto 20-30 miles How far
will you be propelled?

Regards
 
 
Mike
-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Brian Ellis
Sent: Tuesday, June 30, 2009 4:12 PM
To: [log in to unmask]
Subject: Re: [TN] IPA o r Methanol in Ultrasonic Cleaner

There has been at least one fire in a contamination tester that I know
of for certain. The company in question thereafter decreed that all
flammable solutions and products should be used only in metallic
enclosures because the PVC melted, allowing the burning solution to
spread along the floor, causing considerable collateral damage to the
workshop (I think in millions). I have heard of a possible couple of
other minor cases but nothing that I can quote chapter and verse on.

Remember that the vapours from testers are the IPA/water azeotrope and
not pure IPA. Even the small amount of water, not affecting the flash
point, does reduce the ease with which it burns.

As an ex-manufacturer of contamination testers, we took care in the
design to minimise the risk, although it can never be eliminated. I
emphasise that the one that caused all the damage was not of our
manufacture! :-o

By the same token, the bottle of Laphroaig in the CEO's cocktail cabinet
has an EtOH/water azeotrope over the liquid level, but it has a better
aroma and flavour than the contamination tester solution.

Brian

Richard Kraszewski wrote:
> We have done US cleaning using higher molecular weight alcohols and 
> found them to be rather effective, especially in cleaning beneath low 
> stand off components.
> 
> Using lower weight and lower boiling alcohols like MeOH, EtOH or IPA 
> just doesn't work well, so why even take the risk,  albeit the risk is

> rather low.  Remember that ROSE tester solution (~75% IPA) can get 
> rather warm after awhile and I haven't heard about many (any?) fires 
> related to that testing operation.
> 
> 
> Rich Kraszewski
> 
> 
> -----Original Message-----
> From: TechNet [mailto:[log in to unmask]] On Behalf Of John Anselmo
> Sent: Monday, June 29, 2009 10:27 AM
> To: [log in to unmask]
> Subject: [TN] IPA o r Methanol in Ultrasonic Cleaner
> 
> Technet,
> 
> We are being asked by one of our customers to clean some parts 
> (screws, washers, standoffs, feedthrus) in an ultrasonic cleaner with 
> either Methanol or IPA (spectroscopic grade).
> The time in the ultrasonics could be up to 1 hour.
> Does anyone else have experience and recommendations for doing this?
> My main concern is safety.  What type of room or enclosure do we need 
> for this?
> 
> Thanks,
> John Anselmo
> 
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 15.0 To 
> unsubscribe, send a message to [log in to unmask] with following text in

> the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt 
> or
> (re-start) delivery of Technet send e-mail to [log in to unmask]: SET 
> Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the
> posts: send e-mail to [log in to unmask]: SET Technet Digest Search the 
> archives of previous posts at: http://listserv.ipc.org/archives Please

> visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 
> for additional information, or contact Keach Sasamori at 
> [log in to unmask] or 847-615-7100 ext.2815
> -----------------------------------------------------
> 
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 15.0 To 
> unsubscribe, send a message to [log in to unmask] with following text in

> the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt 
> or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: 
> http://listserv.ipc.org/archives Please visit IPC web site 
> http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask]
or 847-615-7100 ext.2815
> -----------------------------------------------------
> 

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0 To
unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing
per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask]
or 847-615-7100 ext.2815
-----------------------------------------------------


***This email, its content, and any files transmitted with it, are
intended solely for the addressee(s) and may be legally privileged
and/or confidential. If you are not the intended recipient, please
contact the sender by return and delete the material from any computer.
Any review, retransmission, dissemination, or other use of, or taking of
any action in reliance upon this information by persons or entities
other than the intended recipient is prohibited.

Messages sent via this medium may be subjected to delays, non-delivery,
and unauthorized alteration. This email has been prepared using
information believed by the author to be reliable and accurate, but
Indium Corporation makes no warranty as to accuracy or completeness.
Indium Corporation does not accept responsibility for changes made to
this email after is was sent. Any opinions or recommendations expressed
herein are solely those of the author. They may be subject to change
without notice.***

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0 To
unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET
Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the
posts: send e-mail to [log in to unmask]: SET Technet Digest Search the
archives of previous posts at: http://listserv.ipc.org/archives Please
visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2