Jowan

I know of no issues arising.

The second part of your query: Yes there are - coatings seal in as  
well as out, and they all breathe, so you need to figure out if you  
can manufacture assemblies that will give no adverse electro-chemical  
activity in later life.

Regards

Graham Naisbitt

Email: [log in to unmask]
Phone: +44 (0)12 5252 1500
Web: www.gen3systems.com

On 30 Jun 2009, at 09:09, Iven, Jowan wrote:

> Hi all,
>
> Does anyone have some knowledge about putting conformal coating on a
> board that has gone through a vapour phase process?
> Are there any known issues?
> Or are there some process considerations regarding cleaning prior to
> conformal coating?
>
>
>
> Thanks in advance
>
> Jowan Iven
>
>
>
> This e-mail and any attachment is confidential and may be legally  
> privileged or otherwise protected from disclosure. If you are not  
> the intended recipient, please notify the sender immediately by  
> returning this e-mail. Neways Electronics NV is not responsible for  
> the improper or incomplete transmission of any e-mail, or for any  
> delay in its receipt.
>
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 15.0
> To unsubscribe, send a message to [log in to unmask] with following  
> text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask] 
> : SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask] 
> : SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/archives
> Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 
>  for additional information, or contact Keach Sasamori at [log in to unmask] 
>  or 847-615-7100 ext.2815
> -----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2