TECHNET Archives

June 2009

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
John Koleszar <[log in to unmask]>
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, John Koleszar <[log in to unmask]>
Date:
Fri, 19 Jun 2009 11:42:12 -0400
Content-Type:
text/plain
Parts/Attachments:
text/plain (73 lines)
Russell,

I have seen this issue on land patterns where one pad is soldermask defined
on a large ground plane.  If this is the case, the ground pad should be
modified to connect to the ground plane with thermals.

Regards,
John

John Koleszar
SMT Manager 
Saline Lectronics, Inc.
710 N. Maple Rd.
Saline, MI 48170
734-944-2120 ext 294
[log in to unmask]


-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Russell Nowland
Sent: Friday, June 19, 2009 11:32 AM
To: [log in to unmask]
Subject: [TN] Float Electrolytic Caps

Hello everyone,

I have an entering situation that my EMS has not been able to figure out.

We use several SMT Electrolytic Capacitors that are sliding off of the pads.

The pad design is per the recommended my the device suppliers and also 
comply with our normal design parameters.  The issue is the device wants to 
slide toward the heel and toe so you end up with pad overhang and clearance 
issues.  The pad design is narrow enough that it is not twisting.

My EMS's current solution is to apply a couple of glue dots under the device

to secure it before the solder reflows.  I am not real crazy for this
process for 
several reasons but they asked permision and it does not violate any 
requirements.

Have any of you seen this and how are you handling it?  Hopefully without 
glue.

Thanks

Russ Nowland

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2