That may not be covered under any standard, because the requirements for CC coverage vary by component, assembly, program, customer, and usage requirements.
Usually, coating over the component body has no value added, as most component bodies are impervious to moisture. The primary purpose of the CC is to prevent moisture buildup on the metal terminations and solder connections on the CCA. 
The coating requirements need to be defined and agreed upon between the user and the supplier (AABUS) and documented on the CCA drawing. They are unique and specific to the product.


-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Ioan Tempea
Sent: Thursday, June 25, 2009 10:51 AM
To: [log in to unmask]
Subject: [TN] Conformal coating coverage

Dear Technos,

 

Since the PCB edges have been already discussed, I would like to get your input on tall components coverage. Do tall parts, like radial TH parts, inductors, electrolytic caps, etc. need to have the vertical sides coated? What about the coils with apparent windings?

 

IPC-610 is not detailed at all at this level and I have quickly browsed IPC-HDBK-830 without being able to find anything. What would be the IPC or MIL standard covering this particular issue?

 

Thank you, 

 

Ioan Tempea, ing.

Ingénieur Principal Fabrication / Sr. Manufacturing Engineer 

 

 

30 ans déjà! - Already 30 years!

950 rue Bergar, Laval, Québec, H7L 5A1

t : 450-967-7100 ext : 244

Mtl : 514-990-5762

f : 450-967-7444

[log in to unmask] <mailto:[log in to unmask]> 

www.digico.cc <http://www.digico.cc/> 

P N'imprimer que si nécessaire - Print only if you must

 


---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2