Oh, yes.  This often happens when the solder mask isn't properly cured,
particularly with HASLed boards.  The flux gets into the mask and doesn't
come out, at least quickly, again  until the mask is exposed to
temperatures above its Tg.   Anyway, I've had customers talk to me about an
ECM problem, thinking it's a flux problem when it was really a mask
problem.  Of course, sometimes customers really have flux problems, but not
always.

 I believe Terry Munson has written about this issue in his advice column
in one of the trade magazines.

Talk to your PCB fabricator.  Sometimes a UV "bump" during mask cure help
alleviate this issue.   Thorough washing with HOT DI water after HASL helps
also.

And yes, HASL fluxes trapped in boards can lead to CAF problems.

Karen Tellefsen - Electrical Testing
[log in to unmask]
908-791-3069



                                                                           
             "Kane, Joseph E                                               
             (US SSA)"                                                     
             <joseph.kane@BAES                                          To 
             YSTEMS.COM>               [log in to unmask]                     
             Sent by: TechNet                                           cc 
             <[log in to unmask]>                                             
                                                                   Subject 
                                       [TN] PB Surface Contamination       
             05/07/2009 09:14                                              
             AM                                                            
                                                                           
                                                                           
             Please respond to                                             
              TechNet E-Mail                                               
                   Forum                                                   
             <[log in to unmask]>                                             
             ; Please respond                                              
                    to                                                     
              "Kane, Joseph E                                              
                 (US SSA)"                                                 
             <joseph.kane@BAES                                             
                YSTEMS.COM>                                                
                                                                           
                                                                           




A cleaned bare PB is exposed to bake or reflow, and comes out with
measurable ionic contamination.  The board is dirtier at the surface
after
a heat excursion.

The contamination isn't coming from the oven, handling, or anything
external.
Heat causes something to move from the inside of the board to the
outside.

We haven't done any ion chromatography or other testing yet to
run this down, but has anyone heard of or experienced anything similar?

In our normal process, we clean everything multiple times, but if the
contaminant builds up under solder mask, or in other areas that are
difficult to clean, we could have SIR or corrosion problems around fine
surface features or in high voltage areas.

And if this ionic contamination doesn't just move up to the surface,
but is somehow moving around inside the board, could it collect in
some places and lead to CAF or other problems?

Joe Kane
BAE Systems
Johnson City, NY


---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2