 No, if you quit and become a consultant, you become richer—the up-side. The down-—you are on the job 24/7/365.

Werner


 


 

-----Original Message-----
From: Inge <[log in to unmask]>
To: [log in to unmask]; [log in to unmask]
Sent: Wed, 27 May 2009 1:45 pm
Subject: Re: [TN] humidity test failure
















So, if I quit, you become richer, can we share your 
extras?


Inge



  
----- Original Message ----- 

  
From: 
  [log in to unmask] 

  
To: [log in to unmask] ; [log in to unmask] 

  
Sent: Wednesday, May 27, 2009 7:08 
  PM

  
Subject: Re: [TN] humidity test 
  failure

  



  
Hi Inge,
"Why do we repeat all failures that have 
  been known for decades?"
Easy, most companies get rid of their experienced 
  people. And the new hires simply do not have the time to learn about anything 
  that happened previously.
——sure keeps consultants busy, 
  though.

Werner


  



  


-----Original Message-----
From: Inge <[log in to unmask]>
To: 
  [log in to unmask]
Sent: Wed, 27 May 2009 
  1:02 pm
Subject: Re: [TN] humidity test failure


  
We 
  had an awful lot of environmental test chambers, and we followed MIL-STD like 
  a blind klinging to his stick. With time, we have realized the questionable 
  relationship between those tests and the unpredictable mother Nature. The 
  exact repetition of temperature up, temp down, dwell, temp down=2
0etc does not 
  always correspond to the erratic reality with endless variations and 
  combinations of condensation and vibration, heat and salt, power switching and 
  deep freeze, sun irradiation and sand blast , very short exposure followed by 
  extremly long one etc etc. I listened to a guy who was a successful design 
  manager, whose motto was 'skip all testing, do the right design or process 
  from the beginnin g' . Easy said, but still interesting topic. Am brought up 
  with MIL-STD, so I'm little ambivalent, but I try to think like him. And, in 
  fact, with all billion hours of testing everything on this planet, should we 
  not have background enough for avoiding all disasters..like corroded ceramic 
  caps, for instance. Why do we repeat 
  all failures that have been known for 
  decades? 
 
Inge 
 
----- Original 
  Message ----- From: "Chris Mahanna" <[log in to unmask]> 
To: 
  <[log in to unmask]> 
Sent: 
  Wednesday, May 27, 2009 6:34 PM 
Subject: Re: [TN] humidity test 
  failure 
 
Hi Wayne, 
 
Agreed. The DUT 
  probably slipped close to, or below dew. Close can be just as bad. And, surely 
  there is trapped ionics. But, I suspect a correlation ranking might show those 
  non-wetted solderable surfaces as your real 
  culprit. 
 
Ability to control the chamber and DUT is highly 
  dependent on absolute humidity. 85/85 is very tough. Anything higher is crazy. 
=2
0 The common 25-65C, 90% is quite difficult without good multi loop control. If 
  you're cycling a heavy assembly you will probably want to use the surface temp 
  as an input to your controller. 
IPC-9201A is a good source of info. 
  NPL has several papers. 
 
Fully processed comb patterns can 
  'survive' 85/85 or 25-65/90 SIR/ECM tests for 1000 hours without cc, but it's 
  not 
  easy. 
 
Chris 
 
 
 
-----Original 
  Message----- 
From: TechNet [mailto:[log in to unmask]] On Behalf Of 
  Thayer, Wayne 
Sent: Tuesday, May 26, 2009 10:01 PM 
To: [log in to unmask] 
Subject: [TN] 
  humidity test failure 
 
Hi Technet 
  Gurus! 
 
I have attached a picture of a part responsible for 
  excess current draw during an extended humidity/temperature cycling test. (I 
  copied Steve so he can hopefully post!) 
 
The board was 
  carefully solvent cleaned, but no SIR test validating the process strips all 
  ionic contamination. The board is in an enclosure where plenty of ionic 
  contaminants are available. 
 
Humidity was supposed to not 
  exceed 90% and was to be non-condensing during cycling. There were a handful 
  of components which displayed similar deposits on the same circuit board. 
  These were the only parts biased during the humidity test. I believe the 
  evidence suggests at least some condensation occurred. To me the deposits look 
  like salts. But what do
 "the experts" think? 
 
Is there any 
  rule of thumb as to humidity levels where we are nuts to try to survive 
  without conformal coating? Part of the adjacent circuitry contains RF devices 
  and those guys get panic-stricken when told we probably n eed to conformal 
  coat! 
 
Wayne Thayer 
 
This e-mail and any 
  files transmitted with it may be proprietary and are intended solely for the 
  use of the individual or entity to whom they are addressed. If you have 
  received this e-mail in error please notify the sender. 
Please note 
  that any views or opinions presented in this e-mail are solely those of the 
  author and do not necessarily represent those of ITT Corporation. The 
  recipient should check this e-mail and any attachments for the presence of 
  viruses. ITT accepts no liability for any damage caused by any virus 
  transmitted by this 
  e-mail. 
 
--------------------------------------------------- 
Technet 
  Mail List provided as a service by IPC using LISTSERV 15.0 
To 
  unsubscribe, send a message to [log in to unmask] with following text 
  in 
the BODY (NOT the subject field): SIGNOFF Technet 
To 
  temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or 
  (MAIL) 
To receive ONE mailing per day of all the posts: send e-mail 
  to [log in to unmask]: SET Technet 
  Digest 
Search the archives of previous posts a
t: http://listserv.ipc.org/archives 
Please visit IPC 
  web site http://www.ipc.org/contentpage.asp?Pageid =4.3.16 for 
  additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 
  ext.2815 
----------------------------------------------------- 
 
--------------------------------------------------- 
Technet 
  Mail List provided as a service by IPC using LISTSERV 15.0 
To 
  unsubscribe, send a message to [log in to unmask] with following text 
  in 
the BODY (NOT the subject field): SIGNOFF Technet 
To 
  temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or 
  (MAIL) 
To receive ONE mailing per day of all the posts: send e-mail 
  to [log in to unmask]: SET Technet 
  Digest 
Search the archives of previous posts at: http://listserv.ipc.org/archives 
Please visit IPC 
  web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for 
  additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 
  ext.2815 
----------------------------------------------------- 
   
--------------------------------------------------- 
Technet 
  Mail List provided as a service by IPC using LISTSERV 15.0 
To 
  unsubscribe, send a message to [log in to unmask] with following text 
  in 
the BODY (NOT the subject fiel d): SIGNOFF Technet 
To 
  temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or 
  (MAIL) 
To receive ONE mailing per day o
f all the posts: send e-mail 
  to [log in to unmask]: SET Technet 
  Digest 
Search the archives of previous posts at: http://listserv.ipc.org/archives 
Please visit IPC 
  web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for 
  additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 
  ext.2815 
----------------------------------------------------- 


  



 


---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2