I need to amend this and stated that I made a typo in the title and in fact
meant dry-film, not LPI.
 
Thanks,
Kevin


-----Original Message-----
From: Kevin Glidden [mailto:[log in to unmask]] 
Sent: Monday, April 13, 2009 12:45 PM
To: [log in to unmask]
Subject: [TN] Info on LPI tenting of vias, both sides

Hello everyone,
 
I am looking for information on the potential pitfalls of using LPI via
tenting on both sides, leaving an air pocket in the vias.  Application is
NOT Pb-Free.
 
I located this article description, and wanted to see if anyone had it, but
other information, inputs, or articles are also welcome:
 

Title: An Evaluation of Via Hole Tenting with Solder Mask Designed to Pass
MIL-P-55110D Thermal Shock Requirements


Author(s): J.J. Davignon, F. Gray


Journal:  <http://www.emeraldinsight.com/0305-6120.htm> Circuit World

 
Thanks!
 

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0 To
unsubscribe, send a message to [log in to unmask] with following text in the
BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet
NOMAIL or (MAIL) To receive ONE mailing per day of all the posts: send
e-mail to [log in to unmask]: SET Technet Digest Search the archives of
previous posts at: http://listserv.ipc.org/archives Please visit IPC web
site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2