IPC-600-6012 Archives

April 2009

IPC-600-6012@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
"Whittaker, Dewey (EHCOE)" <[log in to unmask]>
Reply To:
(Combined Forum of D-33a and 7-31a Subcommittees)
Date:
Thu, 30 Apr 2009 13:53:37 -0700
Content-Type:
text/plain
Parts/Attachments:
text/plain (344 lines)
Too many rewrites of IPC-6012, I'm starting to fray. Thanks for noticing.
Dewey 

-----Original Message-----
From: IPC-600-6012 [mailto:[log in to unmask]] On Behalf Of Lance A Auer
Sent: Thursday, April 30, 2009 1:50 PM
To: [log in to unmask]
Subject: Re: [IPC-600-6012] Reflow testing

Dewey,

        You are in rare form!  Again.

Lance




"Whittaker, Dewey (EHCOE)" <[log in to unmask]> 
Sent by: IPC-600-6012 <[log in to unmask]>
04/30/2009 11:47 AM
Please respond to
"(Combined Forum of D-33a and 7-31a Subcommittees)" <[log in to unmask]>


To
[log in to unmask]
cc

Subject
Re: [IPC-600-6012] Reflow testing






To cause stress
Without a mess 
Nothing says lovin 
Like specs on a oven
Dewey

-----Original Message-----
From: IPC-600-6012 [mailto:[log in to unmask]] On Behalf Of John Perry
Sent: Thursday, April 30, 2009 11:36 AM
To: [log in to unmask]
Subject: Re: [IPC-600-6012] Reflow testing

Hi Wendi and All,

Method 2.6.27 should be released sometime next week on the IPC-TM-650 
website.  I'm also putting together a web page of providers of thermal 
ovens that can meet the profiles in that method.

Regards,

John Perry
Technical Project Manager
IPC - Association Connecting Electronics Industries®
3000 Lakeside Drive # 309S
Bannockburn, IL 60015-1249 USA
+1 847-597-2818 (tel)
+1 847-615-7105 (fax)
+1 847-615-7100 (Main)
[log in to unmask]
www.ipc.org



-----Original Message-----
From: IPC-600-6012 [mailto:[log in to unmask]] On Behalf Of Whittaker, 
Dewey (EHCOE)
Sent: Thursday, April 30, 2009 1:07 PM
To: [log in to unmask]
Subject: Re: [IPC-600-6012] Reflow testing

It is not officially released. Ask John Perry for ERD.
Dewey

-----Original Message-----
From: IPC-600-6012 [mailto:[log in to unmask]] On Behalf Of Wendi Boger
Sent: Thursday, April 30, 2009 10:59 AM
To: [log in to unmask]
Subject: Re: [IPC-600-6012] Reflow testing

Thanks Dewey.

Do you know if the Test Method is release?

-----Original Message-----
From: IPC-600-6012 [mailto:[log in to unmask]] On Behalf Of Whittaker, 
Dewey (EHCOE)
Sent: Thursday, April 30, 2009 10:25 AM
To: [log in to unmask]
Subject: Re: [IPC-600-6012] Reflow testing





Wendi,



The procurement documentation shall specify the thermal stress test method 
to be used to meet the requirement of 3.6.1.   Selection shall be from 
those depicted in 3.6.1.1, 3.6.1.2 and 3.6.1.3. If not specified (see 
5.1), the default shall be per Table 1-2.



During the selection process, the user should take into consideration the 
following when determining the appropriate thermal stress test method:



*     Wave solder, selective solder, hand solder assembly processes (see 
3.6.1.1)

*     Conventional (eutectic) reflow processes (see 3.6.1.2)

*     Lead-free reflow processes (see 3.6.1.3)



Table 1-2 Default Requirements

Category

Default Selection

Performance Class

Class 2

Material

Epoxy-Glass Laminate

Final Finish

Finish X

Minimum Starting Foil

1/2 oz. for all internal and external layers except Type 1 which shall 
start with 1 oz.

Copper Foil Type

Electrodeposited

Hole Diameter Tolerance



Plated, components



Plated, via only





Non-plated





(±) 100 µm [3,937 µin]



(+) 80 µm [3,150 µin], (-) no requirement, (may be totally or partially 
plugged)



(±) 80 µm [3,150 µin]

Conductor Width tolerance

Class 2 requirements per 3.5.1

Conductor Spacing tolerance

Class 2 requirements per 3.5.2

Dielectric Separation

90 µm [3,543 µin] minimum

Lateral Conductor Spacing

100 µm [3,937 µin] minimum

Marking Ink

Contrasting color, nonconductive

Solder Mask

Not applied, if not specified

Solder Mask, specified

Class T of IPC-SM-840 if class not specified

Solder Coating

Sn63/Pb37

Solderability Test

Category 2 of J-STD-003

Thermal Stress Test

IPC-TM-650, Method 2.6.8, Condition A

Test Voltage, Isolation Resistance

40 Volts

Qualification not specified

See IPC-6011





3.6.1 Thermal Stress Testing Test coupons or produc­tion PBs shall be 
thermally stressed.  Per the applicable criteria listed in 1.3.3, one or 
more of the following Test Methods shall be required.



3.6.1.1 Thermal Stress Testing, Method 2.6.8 Test coupons or production 
PBs shall be thermally stressed in accordance with IPC-TM-650, Method 
2.6.8, Test condition A.



3.6.1.2 Thermal Stress Testing, Method 2.6.27 (230 °C)Test coupons or 
production PBs shall be thermally stressed in accordance with IPC-TM-650, 
Method 2.6.27, 230° C Reflow Profile.



3.6.1.3 Thermal Stress Testing, Method 2.6.27 (260 °C)Test coupons or 
production PBs shall be thermally stressed in accordance with IPC-TM-650, 
Method 2.6.27, 260° C Reflow profile.



3.6.1.4 Deviations to Thermal Stress Testing Deviations to these 
requirements shall be AABUS.



Now you are at the Test Method. We have not changed the old one or its 
requirement for use. The default in the new one is 6 X 260°C, the last 
time I looked.

Dewey

















-----Original Message-----

From: IPC-600-6012 [mailto:[log in to unmask]] On Behalf Of Wendi Boger

Sent: Thursday, April 30, 2009 7:02 AM

To: [log in to unmask]

Subject: [IPC-600-6012] Reflow testing



Everyone,







     I have a quick question.  When reviewing my notes from the meeting

I noted that the new reflow thermal stress frequency would be 1X reflow

= 1X solder float.  I have a final draft of the 2.6.27 test method and

it shows 6x reflow cycles.  Are we equating 1X solder float to 6X

reflow?







     Is the test method released yet?











Wendi Boger

The following line is added for your protection and will be used for 
analysis if this message is reported as spam:

(Raytheon Analysis: IP=216.203.207.56; [log in to unmask]; 
[log in to unmask]; date=Apr 30, 2009 6:44:47 PM; 
subject=Re: [IPC-600-6012] Reflow testing)