Hi Dave,
In my experience a flex being panelized is still not very accurate flex
to flex. We obtained slightly better results from a 3 up pallet than a
3 up panel.
I have never done an ENIG flex so I can't help there.
Jerry Dengler
Production Manager
Pergamon Corporation
PH: 610-239-0721
Fax: 610-239-0720
-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Dave Connitt
Sent: Thursday, March 05, 2009 3:09 PM
To: [log in to unmask]
Subject: [TN] ENIG Question
Hello All,
I have a question regarding a strange situation regarding reflow
soldering ENIG finish boards.
We have seen a few boards that have what seems to be gold "washing "
down between pads and creating shorts. This seems to come and go. This
is a flex circuit that is placed on a pallet to go through our SMT line.
One other bothersome issue is that we are having difficulty getting
proper solder stencil alignment across all the flexes in the pallet. I
am pushing to have the flex "panelized" from the vendor to increase
positional accuracy but the jury is still out on that.
I suspect these two issues are related. If the solder gets deposited
"off pad"slightly could the washing process be moving some of the gold
in between pads? I attached an example.
Has anybody come across this?
If so, what was the solution?
Thanks,
Dave Connitt CID+
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0 To
unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET
Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the
posts: send e-mail to [log in to unmask]: SET Technet Digest Search the
archives of previous posts at: http://listserv.ipc.org/archives Please
visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|