TECHNET Archives

March 2009

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, Inge <[log in to unmask]>
Date:
Tue, 31 Mar 2009 19:15:34 +0200
Content-Type:
text/plain
Parts/Attachments:
text/plain (78 lines)
Yes Vladimir, zero hits./Inge


----- Original Message ----- 
From: "Vladimir Igoshev" <[log in to unmask]>
To: <[log in to unmask]>
Sent: Tuesday, March 31, 2009 7:07 PM
Subject: Re: [TN] Nikon microscope camera DXM-1200


> Inge,
>
> Have you checked ebay?
>
> Vladimir
> ------Original Message------
> From: Inge
> Sender: TechNet
> To: [log in to unmask]
> ReplyTo: TechNet E-Mail Forum
> ReplyTo: Inge
> Sent: Mar 31, 2009 11:50
> Subject: [TN] Nikon microscope camera DXM-1200
>
> Hi all and a half,
> anyone who happens to have such a one? I need a electric wiring diagram or 
> a
> service manual for the framegrabber board built for that camera. Nikon 
> does
> not give support and I don't   like to pass such a good camera equipment 
> to
> the waste bin (best  camera on the market when I bought it). The program
> works, but the camera framegrabber window on the screen just shows a 
> zigzag
> pattern.  Camera produces 1V p-p video signal on two wires and sync on the
> third (Y), 12 frames a second, a variant on RGB.  I know it's crazy to
> repair on component level, but I use to at least make a try. Old habit. 
> The
> grabber manufacturer is not either service minded (TechnoMedia). You could
> of course buy general framegrabber board for PCI slots, but then you just
> get a picture and no tool box for annotation , measuring, picture options
> etc.
> /Inge
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 15.0
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to 
> [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to 
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/archives
> Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 
> for additional information, or contact Keach Sasamori at [log in to unmask] or 
> 847-615-7100 ext.2815
> -----------------------------------------------------
>
>
>
> SENTEC
> 11 Canadian Road, Unit 7.
> Scarborough, ON M1R 5G1
> Tel: (416) 899-1882
> Fax: (905) 882-8812
> www.sentec.ca
> 

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2